Results 121 to 130 of about 7,564 (188)
Some of the next articles are maybe not open access.

Fault Detection Methods for Three-Level NPC Inverter Based on DC-Bus Electromagnetic Signatures

IEEE transactions on industrial electronics (1982. Print), 2018
This paper proposes two new open-circuit fault detection methods suitable for the diagnosis of power electronics converters. The faulty semiconductor devices are identified using conducted and radiated electromagnetic signatures of the dc bus through ...
Ibtissem Abari   +4 more
semanticscholar   +1 more source

An analysis of the three-level neutral-point clamped (NPC) inverter with two independent DC sources

2012 25th IEEE Canadian Conference on Electrical and Computer Engineering (CCECE), 2012
In addition to its other merits, the three-level neutral-point clamped (NPC) inverter allows two dc sources, which may be an advantage in photovoltaic systems for enhanced maximum power-point tracking capability and higher energy yield. This paper takes a look at the impact of power mismatch between the two dc sources on the performance of the inverter.
H. Ghoddami, A. Yazdani
openaire   +1 more source

Passive balancing of the DC bus midpoint for Neutral Point Clamped (NPC) based Voltage Source Converters

IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society, 2013
This paper presents a passive method to balance the voltage of the split capacitors in Neutral Point Clamped (NPC) based Voltage Source Converters (VSC). The voltage of the two capacitors is equated by connecting a low VA transformer at the AC side of the converter. The transformer is connected in wye configuration and its neutral point is connected to
Aitor Laka   +3 more
openaire   +1 more source

Research on vector control method of neutral-point-clamped(NPC) three-level inverter with bootstrap driver

2013 Fourth International Conference on Intelligent Control and Information Processing (ICICIP), 2013
Diode neutral-point-clamped(NPC) three-level inverter has more significant characteristics than traditional two-level inverter, such as high utilization rate on voltage of the DC side, low harmonics output, small switching stress etc. There has no mature products of three-level inverter with control system until now.
Ping Li, Qingxiao Zhang
openaire   +1 more source

Experimental verification of direct dead-time Control and DC-link neutral-point balancing of a three level neutral-point-clamped (3L-NPC) VSC

2013 IEEE Energy Conversion Congress and Exposition, 2013
The neutral-point balancing of 3L-NPC converter has been studied in many works in the past. However, all state-of-the-art methods have in common that the information of the energy-flow direction is needed. Recently, Direct Dead-time Control (DDTC) has been presented which controls the converter dead-times to balance the dc-link independent from the ...
Michael Sprenger   +4 more
openaire   +1 more source

Offshore wind turbine simulation: Multibody drive train. Back-to-back NPC (neutral point clamped) converters. Fractional-order control

Energy, 2014
This paper is on offshore wind energy conversion systems installed on the deep water and equipped with back-to-back neutral point clamped full-power converter, permanent magnet synchronous generator with an AC link. The model for the drive train is a five-mass model which incorporates the dynamic of the structure and the tower in order to emulate the ...
Seixas, Mafalda   +2 more
openaire   +2 more sources

Managing the DC link neutral potential of the three-phase-four-wire neutral-point-clamped (NPC) inverter in FACTS application

IECON'99. Conference Proceedings. 25th Annual Conference of the IEEE Industrial Electronics Society (Cat. No.99CH37029), 2003
To compensate for the zero sequence current arising from asymmetrical operation of a transmission line, a neutral point clamped (NPC) inverter with a fourth wire must be employed. The most significant challenge arising from controlling of the four-wire NPC inverter consists in stabilizing the neutral point potential at the DC link middle value.
null Xioming Yuan   +2 more
openaire   +1 more source

A Simplified PWM Strategy for a Neutral-Point-Clamped (NPC) Three-Level Converter With Unbalanced DC Links

IEEE Transactions on Power Electronics, 2016
A simplified pulse width modulation (PWM) strategy for a neutral-point-clamped three-level converter with unbalanced dc links is proposed in this paper to achieve high-quality line-to-line output voltages and to maximize the linear modulation range. The simplified strategy takes the direct output voltage modulation by calculating the special solutions ...
Zongbin Ye   +5 more
openaire   +1 more source

Neuro-Computing Vector Classification SVM Schemes to Integrate the Overmodulation Region in Neutral Point Clamped (NPC) Converters

IEEE Transactions on Power Electronics, 2007
Three-level neutral point clamped (NPC) voltage source converters have recently emerged as important alternatives to conventional two-level converter topologies in high-power medium-voltage energy conversion applications, particularly in high performance ac motor drive systems.
Maryam Saeedifard, Alireza Bakhshai
openaire   +1 more source

Discontinuous PWM Modulation Strategy With Circuit-Level Decoupling Concept of Three-Level Neutral-Point-Clamped (NPC) Inverter

IEEE Transactions on Industrial Electronics, 2013
A new pulse width modulation (PWM) strategy which is an alternative approach of the discontinuous PWM (DPWM) for a three-level neutral-point-clamped (NPC) inverter is developed and presented in this paper. The proposed PWM scheme not only takes advantage of the special properties available in NPC inverters, but also reduces the switching loss of the ...
Zhe Zhang   +2 more