Intraocular Pressure Measurement Using Ocular Response Analyzer, Dynamic Contour Tonometer, and Scheimpflug Analyzer Corvis ST [PDF]

open access: yesJournal of Ophthalmology, 2019
Purpose. To compare intraocular pressure (IOP) measurements with Goldmann applanation tonometry (GAT), ocular response analyzer (ORA), dynamic contour tonometer (DCT), and Corvis ST (CST) in healthy subjects. Methods.
Lisa Ramm   +5 more
doaj   +3 more sources

Comparison of biomechanical indices measured by ocular response analyzer between children and elderly: a systematic review [PDF]

open access: yesInternational Journal of Ophthalmology
Biomechanical study of the visual system by ocular response analyzer investigates the inter-structural biological relationships, mechanics, and function of the visual system.
Hassan Hashemi   +4 more
doaj   +4 more sources

Correlation between apical protrusion in the Scheimflug imaging and Corneal Hysteresis and Corneal Resistance factor by Ocular Response Analyzer, among refractive non-keratoconic Egyptian patients [PDF]

open access: yesElectronic Physician, 2015
Introduction: Apical protrusion in the central 4-mm ring in the Scheimflug imaging (Pentacam), both for the anterior and posterior floats as well as Corneal Hysteresis and Corneal Resistance Factor by Ocular Response Analyzer (ORA), generally are ...
Tamer Adel Refai
doaj   +4 more sources

Comparison among Ocular Response Analyzer, Corvis ST and Goldmann applanation tonometry in healthy children [PDF]

open access: yesInternational Journal of Ophthalmology, 2018
AIM: To explore the relationship between different parameters of Ocular Response Analyzer (ORA) and Corvis ST (CST) in a sample of healthy Iranian school-aged children and the relationship between parameters of these 2 instruments against intraocular ...
Ramin Salouti   +9 more
doaj   +4 more sources

Effect of pathological myopia on biomechanical properties: a study by ocular response analyzer [PDF]

open access: yesInternational Journal of Ophthalmology, 2015
AIM: To evaluate the ocular response analyzer (ORA) measurements of patients with pathological myopia in comparison with those of emmetropic control subjects, and to investigate the correlation between these ORA measurements and spherical equivalent (SE).
Veysi Öner   +3 more
doaj   +4 more sources

Ocular response analyzer parameters in healthy, keratoconus suspect and manifest keratoconus eyes [PDF]

open access: yesOman Journal of Ophthalmology, 2015
Background: To evaluate and compare corneal biomechanical indices and their specificity among keratoconus (KC), keratoconus suspect (KCS), and normal eyes (NL) before and after controlling potential confounders.
Mehrdad Mohammadpour   +5 more
doaj   +3 more sources

The Relationship between Corvis ST Tonometry and Ocular Response Analyzer Measurements in Eyes with Glaucoma. [PDF]

open access: yesPLoS ONE, 2016
It is important to compare the results of Corneal Visualization Scheimpflug Technology instrument (CST) measurements and Reichert Ocular Response Analyzer (ORA) parameters.
Masato Matsuura   +7 more
doaj   +4 more sources

Keratoconus cone location influences ocular biomechanical parameters measured by the Ocular Response Analyzer [PDF]

open access: yesEye and Vision
Background Keratoconus is characterized by asymmetry in the biomechanical properties of the cornea, with focal weakness in the area of cone formation. We tested the hypothesis that centrally-measured biomechanical parameters differ between corneas with ...
Phillip T. Yuhas   +3 more
doaj   +2 more sources

Tonographic Effect of Ocular Response Analyzer in Comparison to Goldmann Applanation Tonometry. [PDF]

open access: yesPLoS ONE, 2017
The tonographic effect is a phenomenon of intraocular pressure (IOP) reduction following repeated tonometry. This study examines whether the tonographic effect occurs following IOP measurement performed with Ocular Response Analyzer (ORA).Both eyes of 31
Martin Zimmermann   +4 more
doaj   +2 more sources

Intraocular pressure and ocular biomechanical parameters vary between generations of the ocular response analyzer in healthy and ectatic eyes [PDF]

open access: yesFrontiers in Medicine
IntroductionThis study evaluated the agreement between a third-generation (G3) ocular response analyzer (ORA) and a first-generation (G1) ORA, and tested the ability of the keratoconus match index (KMI) to identify keratoconus.MethodsHealthy participants
Phillip T. Yuhas   +5 more
doaj   +2 more sources