Results 81 to 90 of about 3,836 (202)

Comparison of survival for super high-flux hemodialysis (SHF-HD) with high albumin leakage versus online hemodiafiltration or SHF-HD with low albumin leakage: the SUPERB study

open access: yesRenal Replacement Therapy, 2023
Background Survival is equivalent between super high-flux hemodialysis (SHF-HD) and online hemodiafiltration (OHDF) with similar albumin leakage. According to the 2013 Japanese dialyzer performance classification, survival on HD is optimal when a type II
Kazuyoshi Okada   +6 more
doaj   +1 more source

Impact of Vitamin E‐Coated Membrane Hemodiafilter on Serum Albumin Redox State in the Acute Kidney Injury Pig Hemodialysis Model

open access: yesArtificial Organs, Volume 49, Issue 6, Page 1076-1081, June 2025.
The effect of vitamin E‐coated high‐flux hemodiafilter on the redox state of serum albumin, which forms the largest fraction of reactive sulfhydryl, has not been reported. Hemodiafiltration (HDF) with (V‐RATM) and without a vitamin E‐coated hemodiafilter (ABHTM) was performed in an acute kidney injury pig model to determine whether changes in the serum
Shouichi Fujimoto   +5 more
wiley   +1 more source

Evaluation of Light Chain Removal Rates in Blood Purification Therapy for Light Chain Cast Nephropathy

open access: yesKidney Medicine
Acute kidney injury is a crucial prognostic factor for multiple myeloma. The most common cause is light chain cast nephropathy. The primary pathology of light chain-induced acute kidney injury involves obstruction of distal tubules due to the interaction
Hisashi Kamido   +10 more
doaj   +1 more source

Nationwide survey of patients with acute liver failure and late‐onset hepatic failure in Japan seen between 2016 and 2021

open access: yesHepatology Research, Volume 55, Issue 6, Page 932-947, June 2025.
Abstract Aim A nationwide survey was conducted to clarify the recent status of patients with acute liver failure (ALF) and late‐onset fulminant hepatitis (LOHF) in Japan. Methods Two‐step surveys were performed annually targeting 782 hospitals, focusing on patients meeting the Japanese diagnostic criteria.
Nobuaki Nakayama   +23 more
wiley   +1 more source

Comparison of intradialytic plasma volume change between online hemodiafiltration and standard hemodialysis

open access: yesRenal Replacement Therapy, 2018
Background Intradialytic plasma volume change (IPVC) owing to ultrafiltration is a dominant cause of intradialytic hypotension (IDH). Lower occurrence of IDH in hemodiafiltration (HDF) than in standard hemodialysis (std-HD) indicates that HDF has ...
Masayuki Tanemoto   +3 more
doaj   +1 more source

Interpretable machine learning models for the prediction of all‐cause mortality and time to death in hemodialysis patients

open access: yesTherapeutic Apheresis and Dialysis, Volume 29, Issue 2, Page 220-232, April 2025.
Abstract Introduction The elevated mortality and hospitalization rates among hemodialysis (HD) patients underscore the necessity for the development of accurate predictive tools. This study developed two models for predicting all‐cause mortality and time to death—one using a comprehensive database and another simpler model based on demographic and ...
Minjie Chen   +7 more
wiley   +1 more source

Impact of convective clearance on intra‐dialytic potassium removal in chronic dialysis patients

open access: yesArtificial Organs, Volume 49, Issue 2, Page 300-309, February 2025.
The impact of convective clearance offered by on‐line haemodiafiltration (OL‐HDF) on intra‐dialytic potassium removal is unknown. We included 141 patients from a single centre with 21 treated with high‐flux haemodialysis (HD) and 120 with OL‐HDF. Patients on OL‐HDF and HD has similar intra‐dialytic potassium removal.
David A. Jaques   +3 more
wiley   +1 more source

Optimization of Ibuprofen Route and Dosage to Enhance Protein-Bound Uremic Toxin Clearance During Hemodialysis

open access: yesToxins
Protein-bound uremic toxins (PBUT), particularly indoxyl sulphate (IS) and p-cresyl sulphate (pCS), are poorly removed by conventional haemodialysis because of their strong albumin binding.
Víctor Joaquín Escudero-Saiz   +10 more
doaj   +1 more source

Comparison of hemodialysis urea clearance using spent dialysate and Kt/Vurea equations

open access: yesArtificial Organs, Volume 49, Issue 1, Page 85-92, January 2025.
We measured urea clearance using standard Kt/Vurea equations with calculation of total body waster using Watson V or bioimpedance analysis and compared the values to Kt/V urea calculated using solute‐solver Lite online program and urea clearance measured from collection of effluent dialysate.
Priyanka Khatri, Andrew Davenport
wiley   +1 more source

High-volume haemofiltration for sepsis in adults [PDF]

open access: yes, 2017
BACKGROUND: Severe sepsis and septic shock are leading causes of death in the intensive care unit (ICU), despite advances in the treatment of patients with severe sepsis and septic shock, including early recognition, appropriate treatment with ...
Blackwood, Bronagh   +5 more
core   +2 more sources

Home - About - Disclaimer - Privacy