Results 11 to 20 of about 207,280 (252)
The inevitable replacement of electro-mechanical protection relays with more recently-developed microprocessor-based protection relays poses challenges to engineer, one of which is migration from existing manufacturer’s non-standard inverse time ...
Bagus Brahmantya Gautama
doaj +3 more sources
The optimum setting of directional overcurrent relays (DOCRs) is required to avoid miscoordination and avail fast response. To fulfill these requirements, it is required to prefer optimization techniques and modifications in objective functions (OF ...
Shanker D. Godwal +4 more
doaj +2 more sources
Investigation of Overcurrent Relay Tripping Time Protection Using PSCAD Software
This paper studied the modelling of 132/33/11kV overcurrent protection by using PSCAD software. The objective of this project is to compare between IEC 60255 Standard and IEEE C37.112 Standard overcurrent relay response time in the event of fault ...
Mohd Hendra Hairi +3 more
doaj +3 more sources
Overcurrent Relay for Generation Distribution Utilization [PDF]
Distributed Generation (DG) is the production of electricity from a variety of renewable energy sources that is closer to the customer and load. The addition of distributed generation sources to the distribution networks alters the characteristics of distribution system and has an influence on its protection coordination.
Sarah Herul Anuar, Rasyidah Mohd Idris
openaire +2 more sources
Microgrid Protection through Adaptive Overcurrent Relay Coordination
The inclusion of distributed energy resources (DER) in Microgrids (MGs) comes at the expense of increased changes in current direction and magnitude.
Haneen Bawayan, Mohamed Younis
semanticscholar +3 more sources
Conventional protection schemes in the distribution system are liable to suffer from high penetration of renewable energy source-based distributed generation (RES-DG).
Mian Rizwan +5 more
doaj +2 more sources
Inverse Definite Overcurrent Relay Response at Pencawang Masuk Utama Pagoh, Johor
This paper focuses on modelling 132/11kV Pencawang Masuk Utama (PMU) Pagoh, Johor for assessing the Inverse Definite Minimum Time (IDMT) overcurrent relay in terms of relay response time using PSCAD software and comparing them with the calculated value.
M. H. Hairi +4 more
doaj +3 more sources
Performance Evaluation of Overcurrent Protection Relay Based on Relay Operation Time (ROT)
Protection system plays an important role in detecting the presence of disorders and may prevent damage that can caused interference. Thus, the reliability of the system to maintain continuity of supply to the load will be improved.
Mohd Hendra Hairi +3 more
doaj +4 more sources
Protection Coordination Index Assessment Using Fuzzy Logic Controller
This paper proposes the assessment method of the protection coordination index (PCI) for overcurrent protection relay and upstream relay. The protection coordination index is an indicator of how properly the equipment is protected by protective relay ...
Choong-Koo Chang +1 more
doaj +1 more source
Optimal Coordination of Directional Overcurrent Relays for Microgrids Using Hybrid Interval Linear Programming - Differential Evolution [PDF]
The relay coordination problem of directional overcurrent has been an active research issue in distribution networks and power transmission. In general, the problem of relay coordination is the nonlinearity of the optimization problem, which increases ...
P. Omidi, S. Abazari, S.M. Madani
doaj +1 more source