Results 41 to 50 of about 489 (178)
ABSTRACT The long‐term hydrophobic stability of silicone rubber (SiR) insulators is essential for their reliability in high‐voltage direct current (HVDC) applications. This study investigates the effect of nano‐silica fillers with varying specific surface areas (SSA = 120, 200 and 300 m2/g) and different concentrations of alumina trihydrate (ATH ...
Mahmoud A. Ali +3 more
wiley +1 more source
Electricity is delivered to end users through generation, transmission, and distribution phases. The most important issues during energy journey is to provide selective, rapid, and safe protection to ensure energy continuity.
Uğur Arifoğlu +2 more
doaj +1 more source
ABSTRACT The development of autonomous electric vehicles (AEVs) represents the convergence of two simultaneous automotive revolutions: electric vehicles (EVs) and autonomous vehicles (AVs). AVs require sensors, decision‐making systems and actuation systems to achieve autonomous driving, whereas EVs require intelligent management and real‐time ...
Ohud Alsadi +5 more
wiley +1 more source
Multiterminal High‐Voltage Direct Current Projects: A Comprehensive Assessment and Future Prospects
ABSTRACT Multiterminal high‐voltage direct current (MT‐HVDC) systems are an important part of modern power systems, addressing the need for bulk power delivery and efficient renewable energy integration. This paper provides a comprehensive overview of recent advances in MT‐HVDC technology, including launched projects and ongoing initiatives.
Mohammad Hossein Mousavi +3 more
wiley +1 more source
Busbar Fault Direction Identification Using Sequences of Displacement Vectors
In this paper, a novel busbar fault direction identification scheme is presented. The proposed scheme is based on sequences of displacement vectors. The proposed algorithm is fast and simple enough to be embedded in a differential relay to assist the percentage‐restraint differential algorithm.
Mostafa Sarlak
wiley +1 more source
The effective functioning and regulation of power systems crucially rely on the coordination of distance and directional overcurrent relays. Accurate fault detection and successful clearing sequences require support for each relay and the maintenance of ...
Mohammadreza Aminian +2 more
doaj +1 more source
ABSTRACT With the growing interest in monitoring and diagnostic techniques for assessing transformer condition, dissolved gas analysis (DGA) stands out as a crucial diagnostic tool to detect electrical and thermal faults in liquid‐immersed transformers.
Gechen Bian +3 more
wiley +1 more source
Standard and proposed non‐standard OCR characteristics. ABSTRACT This study introduces an advanced adaptive protection approach for AC power systems, designed to address key limitations in current clustering‐based relay coordination methods. Using K‐means, hierarchical, and spectral clustering techniques, the proposed scheme classifies grid operating ...
Feras Alasali +6 more
wiley +1 more source
In high‐speed maglev trains, the active guidance system is responsible for centring the vehicle relative to the track, a function that becomes critical under centrifugal forces, crosswinds, and track irregularities. To address the limitations of existing control methods in multi‐disturbance environments, this paper proposes a gap‐loop active ...
Zhiqiang Wang +3 more
wiley +1 more source
This paper proposes the split‐station architecture, which uses high‐temperature superconducting (HTS) cables as ‘virtual bus extensions’ to decouple transformation from distribution in medium‐voltage systems. PYPOWER simulations validated against Project Hydra 13.8 kV specifications demonstrate that a 3‐km HTS link reduces voltage drop by 46 ...
Mohamed Shamseldein
wiley +1 more source