Results 61 to 70 of about 207,280 (252)
Standard and proposed non‐standard OCR characteristics. ABSTRACT This study introduces an advanced adaptive protection approach for AC power systems, designed to address key limitations in current clustering‐based relay coordination methods. Using K‐means, hierarchical, and spectral clustering techniques, the proposed scheme classifies grid operating ...
Feras Alasali +6 more
wiley +1 more source
Digital model of overcurrent relay characteristics
Digital model of overcurrent relay ...
HA Darwish (17758182) +3 more
core +1 more source
This paper proposes the split‐station architecture, which uses high‐temperature superconducting (HTS) cables as ‘virtual bus extensions’ to decouple transformation from distribution in medium‐voltage systems. PYPOWER simulations validated against Project Hydra 13.8 kV specifications demonstrate that a 3‐km HTS link reduces voltage drop by 46 ...
Mohamed Shamseldein
wiley +1 more source
Analysis of overcurrent protection relay settings of a commercial building [PDF]
This paper presents analysis of overcurrent relay settings for the selected commercial building using radial system, Library of Universiti Malaysia Pahang, Pekan Campus. The main software used is Electrical Transient and Analysis Program (ETAP) software.
Nurul Syaqirah, Mohd Sufi
core
This paper proposes integrating polyether ether ketone (PEEK) with a synthetic ester liquid as the composite insulation system for subsea cable connectors. The study commences with a comparative analysis of the electrical performance of PEEK when immersed in a synthetic ester liquid and a mineral oil.
Danny Guana +3 more
wiley +1 more source
This study develops a data‐driven hybrid framework for assessing the condition and risk of converter stations. By combining adaptive thresholding, a condition assessment algorithm and a two‐stage Weibull failure model, it enables early fault detection and quantification of equipment degradation. Case study shows enhanced sensitivity to latent failures,
Peiyuan Zou +7 more
wiley +1 more source
In this study, non-directional overcurrent relay coordination was done in 154/34.5 kV Malatya Teias Hasancelebi transformer centre using League Championship Algorithm (LCA). Standard inverse time characteristic based on IEC 255-3 is used for the relay is
Cengiz Hark +9 more
core +1 more source
This research presents a robust protection coordination strategy using dual‐setting directional overcurrent relays (DS‐DOCRs) and a novel optimisation approach to address challenges in adaptive protection. A modified objective function, incorporating primary and backup relay operating times along with coordination time intervals (CTIs), is designed to ...
Oussama Merabet +4 more
wiley +1 more source
Protection Relay Setting based on Overcurrent Phenomena in Commercial Building
Nowadays, every single distribution system needs to install an appropriate relay to keep the system safe. The operational and commonly recommended relay for distribution systems is the overcurrent (OC) relay.
Hussain, Muhamad Hatta +6 more
core +1 more source
The safe and reliable operation of a distribution network (DN) is closely related to the development of national economy and the improvement of people's living standards.
Qun Ge +3 more
doaj +1 more source