IGBT Gate Boost Drive Technology for Promoting the Overload Capacity of Traction Converter. [PDF]
Zhang Y +7 more
europepmc +1 more source
Multi-timescale energy-aware grid-forming control with self-tuning virtual inductance for battery lifetime enhancement. [PDF]
Zheng L, Liu X.
europepmc +1 more source
The Performance of a Passive Autoranging Method for a Photonic Current Transducer. [PDF]
Fusiek G, Mir B, Niewczas P.
europepmc +1 more source
Related searches:
Neutral displacement overvoltage is harmful to power equipment. A method for suppressing the neutral point displacement overvoltage and its suppression circuit were proposed in this paper to restore it to a normal level. First, it is judged if the neutral point displacement voltage is greater than the set value.
Kun Yu
exaly +2 more sources
Current circuit simulation research on EMU (Electric Multiple Unit) overvoltage has focused on overvoltage amplitude distribution and the oscillation frequency of the operating main circuit breaker overvoltage.
Xianfeng Tang +2 more
exaly +2 more sources
Flexible Neutral Point Displacement Overvoltage Suppression Method Based on Backstepping Control in Unbalanced Distribution Networks [PDF]
Three-phase AC distribution networks are required to operate as symmetrically as possible for optimal performance, but the three-phase-to-ground parameters are asymmetric in the field due to network construction deviation, resulting in the three-phase ...
Mou-Fa Guo, Shuyue Lin, Jian-Feng Xu
exaly +2 more sources
A Neutral Point Overvoltage Suppression Method Based on Backstepping Control With DC Suppression
2021 6th International Conference on Power and Renewable Energy (ICPRE), 2021Mou-Fa Guo
exaly +2 more sources
Overvoltage Suppression for Modular Multilevel Converter With Switch Open-Circuit Fault
IEEE Transactions on Industrial Electronics, 2022hust PengLi, Zhen Wang
exaly +2 more sources
Atmospheric Overvoltages Suppression: In Situ and Analytical Validation
IEEE Transactions on Electromagnetic Compatibility, 2023This article deals with the issues arising from non-adequately designed grounding system of the telecommunication cell tower, in situ experimental investigations, novel system design, and consecutive verification as well as in-depth analysis based on the analytical model.
Tonko Garma +3 more
openaire +3 more sources
Load Rejection Overvoltage Suppression and Parameter Design Method of UHV AC Transmission Line
UHV (ultra-high voltage) by instant AC transmission system is accompanied by huge reactive power transmission. When the load drops sharply, it is easy to produce serious power frequency overvoltage, which is also defined as load rejection overvoltage ...
Ding Yixing, Wang Ma, Rusi Chen
exaly +2 more sources

