Results 1 to 10 of about 892 (179)
In recent years, with the rapid development of offshore wind turbines (WTs), the problem of lightning strikes has become more and more prominent. In order to reduce the failure rate caused by the transient overvoltage of lightning struck offshore WTs ...
Li Zhang +4 more
doaj +3 more sources
In order to suppress the sending end transient overvoltage caused by HVDC commutation failure considering large wind power integration, this paper proposes a coordinated optimization method for the control parameters of DC and wind power, which can ...
Yang Li +3 more
doaj +3 more sources
The hybrid cascaded HVDC system(HC-HVDC) in sending end system is composed of an Line Commutated Converter(LCC) connected in series with a parallel group of Modular Multilevel Converters (MMC).
Jiangshan Liu +5 more
doaj +3 more sources
As a predominant issue within line-commutated converters-based high voltage direct current (DC) transmission systems, commutation failure may trigger transient overvoltage problems and the tripping of large-scale renewable generation sets in hybrid AC/DC
Boyu Qin +4 more
doaj +3 more sources
Study on the Fast Transient Process of Primary Equipment Operation in UHV Fixed Series Capacitors Based on PEEC Method [PDF]
This manuscript proposes a fast transient simulation method based on PEEC to model overvoltage caused by spark gap and disconnecting switch operations in UHV series compensation (FSC).
Baojiang Tian +7 more
doaj +2 more sources
Research on Ultra-Fast Transient Overvoltage Characteristics of Electric Locomotive
Operating overvoltage occurs when the pantograph or main breaker of an electric locomotive is operated, which is prone to causing insulation failure of high-voltage equipment.
Yike Guo +3 more
doaj +3 more sources
The transient overvoltage caused by faults in ultra-high-voltage direct current (UHVDC) transmission lines and alternating current (AC) systems can adversely affect system safety and stability.
Weiwei Yao +13 more
doaj +3 more sources
The fast DC current recovery is widely adopted in the existing Voltage Dependent Current Order Limiter (VDCOL) for Line Commutated Converter-based High Voltage Direct Current (LCC-HVDC) systems to mitigate transient overvoltage in the sending-end grid ...
Bo Pang +6 more
doaj +3 more sources
Simulation and Experimental Research on Overvoltage Measurement of Hybrid CVT [PDF]
The CVT equipment running on site is slightly modified to form a hybrid CVT to achieve transient overvoltage measurement, which is theoretically feasible and practical.
Nie Yu +3 more
doaj +1 more source
A New Quantitative Analysis Method for Overvoltage in Sending End Electric Power System With UHVDC
With the development of renewable electric power generation and ultra-high voltage direct current (UHVDC) transmission, the transient overvoltage in the sending end electric power system with UHVDC occurs, but it is lack of quantitative transient voltage
Ancheng Xue +8 more
doaj +1 more source