Results 21 to 30 of about 892 (179)
Considering the Switching Strategy of the Transmitting Wind Power to Deal with the DC Blocking Fault Under the Constraint of Transient Overvoltage [PDF]
[Objective] For the power grid with high penetration of new energy,measures such as rapid shut-off or emergency reduction of the power of new energy stations are often used to deal with DC lockout faults,but the cutting will weaken the strength of the ...
MA Qiang, YIN Chunya, QIN Yanhui, MA Xing, TANG Zhipeng
doaj +1 more source
Modeling and Analysis of Transient Overvoltage of Direct Drive Wind Turbine Under Symmetrical Faults
Large-scale wind power bases typically adopt UHVAC/UHVDC transmission systems for power export, with weak grid strength in the collection area. After short-circuit faults, transient overvoltage issues are prone to occur, making it urgent to study the ...
Hongbo LUO +3 more
doaj +1 more source
This paper presents an electromagnetic transient analysis of lightning-initiated overvoltage stresses of the step-up transformers installed inside a nacelle of onshore, multi-megawatt, new-generation wind turbines.
Petar Sarajcev, Antun Meglic, Ranko Goic
doaj +1 more source
To address the problem of winding turn-to-turn breakdown faults in 35 kV dry-type transformers in wind farms under overvoltage conditions, this paper establishes a simulation model based on the structural dimensions and material parameters of the ...
Ziheng Pu +4 more
doaj +1 more source
Beyond the hype surrounding the self‐healing properties of gallium‐based liquid metals (Ga‐LMs), this perspective critically examines their functional roles in metal‐ion batteries, highlighting both their underlying merits and the often‐overlooked challenges, including non‐representative design and testing configurations, performance overestimations ...
Turly P. P. Sumanasekara +7 more
wiley +1 more source
During the asymmetric short-circuit period and the fault recovery stage of the renewable energy collection system, the non-fault phase and the PCC point show transient overvoltage characteristics, respectively, which threaten the safe and stable ...
Biyang Wang +4 more
doaj +1 more source
Laser‐Textured Field‐Engineered Interface for Robust Dry‐Processed Cathodes in Lithium‐Ion Batteries
Laser‐patterned dry electrodes applied to current collectors could serve as a promising alternative to the limitations of conventional dry electrodes. Laser technology provides a fast and simple method to enhance the surface roughness of current collectors, improving the adhesion at the electrode–current collector interface.
Chaerin Jung +8 more
wiley +1 more source
A Comprehensive Review of Fault‐Current Limiter Technologies for Smart and Resilient Power Systems
This review compares superconducting, solid‐state, and hybrid fault‐current limiters (FCLs) for modern alternating current, direct current, and hybrid grids. It shows that optimal FCL selection depends on fault characteristics, network configuration, voltage level, protection coordination, and resilience requirements rather than on a universally ...
Abdelrahman Farghly +5 more
wiley +1 more source
Overvoltage and insulation coordination of flexible DC distribution network with DC circuit breaker
With the continuous application and popularization of distributed energy, DC power distribution will become the mainstream form of future power distribution system.
LIU Shuhan +5 more
doaj +1 more source
In regions with extensive wind power collection, the grid’s robustness diminishes, and transient overvoltage phenomena during the restoration phase following an AC short-circuit fault pose significant challenges to secure and stable operation ...
Xu Tian +5 more
doaj +1 more source