Results 41 to 50 of about 1,696 (209)
ABSTRACT With increasing demands for fire safety and environmental friendliness, retrofilling transformers with alternative insulating liquids has become a growing trend. However, retrofilling power transformers remains uncertain, as more residual mineral oil compromises K‐class flame retardancy, and its impact on environmental performance has yet to ...
Zhenfu Tang +5 more
wiley +1 more source
Modelling and identification for reduction of overvoltage transients
The main problems that appear when using a long cable connection between a Variable Frequency Drive (VFD) and the AC motor are over-voltages and bearing currents. The last one concerns especially EMC, while the over-voltage transients can be fatal to the motor.
Capitaneanu, Stefan +4 more
openaire +2 more sources
ABSTRACT Data from five rocket‐triggered lightning flashes are adopted to analyse the correlated transient response of buried cables and lightning channel radiations. These five flashes have the same termination point that is right above the buried cables and involve a total of 32 return strokes.
Mi Zhou +9 more
wiley +1 more source
ABSTRACT Currently, limited research exists on the structural response and protection methods of the converter transformer tank for ± 800 kV ultra‐high voltage direct current transmission project to high energy arc faults. This research investigates the dynamic response and the vulnerable areas of the ultra‐high voltage converter transformer under the ...
Ke Wang +5 more
wiley +1 more source
As the ‘dual carbon’ goals continue to advance in China, the grid‐connected scale of new energy power generation equipment such as wind power and photovoltaic power is constantly increasing.
Shiyun Xu +4 more
doaj +1 more source
The growing reliance on high-power high-voltage direct current (HVDC) transmission systems has intensified challenges associated with transient AC overvoltage induced by commutation failures resulting from converter operation characteristics.
Xiyu Yin +6 more
doaj +1 more source
Infeasibility Analysis of Half-Wavelength Transmission Systems
This paper analyzes the infeasibility of half-wavelength transmission systems in the aspects of power-frequency overvoltage and synchronization stability. The circuit model of the long-distance transmission system is established at first for steady-state
Zheng Xu, Jian Yang, Nengjin Sheng
doaj +1 more source
Study on Impurity Particle Detection in Transformer Oil Based on Microflow Imaging Method
ABSTRACT The concentration of particles in transformer oil has a significant influence on its electrical performance, making oil cleanliness a critical parameter in the operation and maintenance of power transformers. However, the light obstruction (LO) method recommended by current standards has inherent limitations, including low sensitivity to ...
Chen Chen +6 more
wiley +1 more source
Research on Lightning Overvoltage Characteristics of High-Voltage Diode Rectifier
Failure of the high-voltage diode rectifier caused by lightning will cause huge losses. The traditional analysis of overvoltage induced by the high-voltage diode rectifier shell under lightning stroke cannot adapt to the overvoltage process caused by ...
Guoping Peng +6 more
core +1 more source
Transient Overvoltage Analysis in the Medium Voltage Substations Based on Full-Wave Modeling of Two-layer grounding System [PDF]
In this paper, a comprehensive investigation of substation grounding soil structure effects on switching/lightning transients is presented. The full-wave computational solution Method of Moments (MoM) is adopted to solve Maxwell's equations.
Bak, Claus Leth +3 more
core +1 more source