Results 51 to 60 of about 892 (179)
Electromagnetic transient suppression for thyristor switch‐based auto‐passing neutral section system
The auto‐passing neutral section (ANS), applied in the traction substation or section post (SP), is one of the effective methods to improve the continuity of power supply, and the electromagnetic transient is the key issue impacting its application value.
Wu Liran +3 more
doaj +1 more source
For ±800 kV MMC‐HVDC overhead‐cable hybrid lines, monopolar grounding faults drive the maximum healthy‐pole overvoltage to 2.004 p.u., notably above the 1.824 p.u. of a full‐overhead line. Cable‐internal faults further produce a damped, quasi‐periodic zero‐crossing oscillation whose period scales with the fault‐to‐junction distance, offering a novel ...
Xiangyu Yang +4 more
wiley +1 more source
Overvoltages and Transients Identification In On-line Bushing Monitoring
Overvoltages and transients are sometimes recognized as the cause of bushings’ rapid failure. This fact is confirmed by the studies published at the 2018 CIGRE session. They can also initiate dangerous resonance phenomena in transformer windings. The identification of very fast overvoltages characterized by high dynamics of voltage changes, so-called ...
Gil, Wieslaw +2 more
openaire +3 more sources
Low‐concentration multi‐salt DME electrolytes show composition‐dependent solvation. LiNO3‐containing formulations markedly improve lithium reservoir preservation, while FSI and TFSI respond differently to nitrate: FSI retains contact‐associated environments, whereas TFSI shifts toward predominantly noncontact configurations.
Andrea Gentile +5 more
wiley +1 more source
Tracking Battery Microstructural Degradation Through Directional Thermal Transport Signatures
In lithium‐ion batteries, heat conduction varies between the through‐plane and in‐plane directions because of the cell's layered structure. Therefore, cell degradation influences thermal conductivity in each direction uniquely due to detailed microstructural and compositional changes.
Mohammad Shoghi Tekmedash +6 more
wiley +1 more source
Context: This research presents two main results: (i) the application of deep learning networks for the classification of transient overvoltage in the frequency domain, and (ii) the physical-mathematical formulation for the coupling of atmospheric ...
Luis Eduardo Perdomo Orjuela +2 more
doaj +1 more source
Metal‐coated carbon fiber electrodes transform aqueous redox flow batteries by accelerating negative‐electrode redox kinetics, suppressing hydrogen evolution, and regulating metal plating. Standardized testing, operando mechanistic studies, and techno‐economic validation are essential for practical, scalable deployment.
Ganesan Srividhya +4 more
wiley +1 more source
Study on characteristics of slow-front overvoltage of ±1100 kV UHVDC transmission lines
The ±1100 kV Zhundong–Wannan ultra high-voltage direct current (UHVDC) transmission project is under construction in China, which has the highest operating voltage in the world.
Jiqun Zhong +5 more
doaj +1 more source
Three La0.7Sr0.3BO3−δ (B═Co, Fe, Cr) anodes were studied for CH4‐assisted electrolysis at high temperature. Methane oxidation depolarizes the cell, as evidenced by electrochemical and gas‐phase analysis. LSCr shows high stability but limited depolarization; LSCo/LSFe activate via B‐site segregation and surface defects, enhancing performance. A critical
Manuel Legrée +2 more
wiley +1 more source
Review of overhead line defect inspection based on deep learning and UAV images
Line commutated converter based high voltage direct current (LCC-HVDC) is the key to large-scale grid connection and long-distance transmission of renewable energy. However, faults such as DC blocking and commutation failure may lead to short-term excess
ZHOU Wenqing, LIU Gang
doaj +1 more source