Results 51 to 60 of about 613,249 (208)
The growing reliance on high-power high-voltage direct current (HVDC) transmission systems has intensified challenges associated with transient AC overvoltage induced by commutation failures resulting from converter operation characteristics.
Xiyu Yin +6 more
doaj +1 more source
Study on characteristics of slow-front overvoltage of ±1100 kV UHVDC transmission lines
The ±1100 kV Zhundong–Wannan ultra high-voltage direct current (UHVDC) transmission project is under construction in China, which has the highest operating voltage in the world.
Jiqun Zhong +5 more
doaj +1 more source
The multiple reignitions of vacuum circuit braker (VCB) while switching off the shunt reactor in an offshore wind farm (OWF) would produce a high overvoltage. The post‐arc process of ion movement in the vacuum interrupter is analysed.
Zhi Zheng +5 more
doaj +1 more source
ABSTRACT The double‐break vacuum circuit breakers (VCBs) that utilize series break technology effectively increase the switching capability for capacitive currents, elevate the withstand voltage level, and reduce the likelihood of restrike, all without compromising the breaking capacity for short‐circuit currents.
Yun Geng +6 more
wiley +1 more source
Aiming at the transient overvoltage problem in the new energy high-penetration area of the feeder due to DC bipolar blocking fault, a converter bus reactive power allocation capacity optimization scheme is proposed with the constraint that the transient ...
Xinyue LI +4 more
doaj +1 more source
ABSTRACT The alternate arm converter (AAC) is one of the most efficient multilevel topologies based on voltage source converters (VSCs), which has recently gained attention in various applications, particularly in high voltage direct current (HVDC) systems.
Ehsan Akbari, Milad Samady Shadlu
wiley +1 more source
Lightning caused overvoltages on power transformers recorded by on-line transient overvoltage monitoring system [PDF]
Transient overvoltages generated by lightning strikes or switching operations represent a significant risk to bushings and windings of power transformers.
Keitoue, Samir +5 more
core +1 more source
Review of overhead line defect inspection based on deep learning and UAV images
Line commutated converter based high voltage direct current (LCC-HVDC) is the key to large-scale grid connection and long-distance transmission of renewable energy. However, faults such as DC blocking and commutation failure may lead to short-term excess
ZHOU Wenqing, LIU Gang
doaj +1 more source
Infeasibility Analysis of Half-Wavelength Transmission Systems
This paper analyzes the infeasibility of half-wavelength transmission systems in the aspects of power-frequency overvoltage and synchronization stability. The circuit model of the long-distance transmission system is established at first for steady-state
Zheng Xu, Jian Yang, Nengjin Sheng
doaj +1 more source
ABSTRACT To effectively suppress transient overvoltages in HVDC systems, the design and experimental validation of a multi‐module series controllable arrester are presented. The voltage‐limiting performance, series voltage equalisation capability, and robustness under fault conditions in high‐voltage scenarios require further research.
Tai Yang +4 more