Results 51 to 60 of about 613,249 (208)

Research on transient AC overvoltage suppression method of DC sending end based on novel fast-excitation MCR

open access: yesInternational Journal of Electrical Power & Energy Systems
The growing reliance on high-power high-voltage direct current (HVDC) transmission systems has intensified challenges associated with transient AC overvoltage induced by commutation failures resulting from converter operation characteristics.
Xiyu Yin   +6 more
doaj   +1 more source

Study on characteristics of slow-front overvoltage of ±1100 kV UHVDC transmission lines

open access: yesThe Journal of Engineering, 2018
The ±1100 kV Zhundong–Wannan ultra high-voltage direct current (UHVDC) transmission project is under construction in China, which has the highest operating voltage in the world.
Jiqun Zhong   +5 more
doaj   +1 more source

Investigation on overvoltage caused by vacuum circuit breaker switching off shunt reactor in offshore wind farms

open access: yesHigh Voltage, 2022
The multiple reignitions of vacuum circuit braker (VCB) while switching off the shunt reactor in an offshore wind farm (OWF) would produce a high overvoltage. The post‐arc process of ion movement in the vacuum interrupter is analysed.
Zhi Zheng   +5 more
doaj   +1 more source

The Impact of Various Contact Structures on the Microscopic Surface Condition of Vacuum Interrupters During Capacitive Switching

open access: yesHigh Voltage, EarlyView.
ABSTRACT The double‐break vacuum circuit breakers (VCBs) that utilize series break technology effectively increase the switching capability for capacitive currents, elevate the withstand voltage level, and reduce the likelihood of restrike, all without compromising the breaking capacity for short‐circuit currents.
Yun Geng   +6 more
wiley   +1 more source

Transient overvoltage suppression measures for new energy high penetration system at the sending end under bipolar blocking fault

open access: yes电力工程技术
Aiming at the transient overvoltage problem in the new energy high-penetration area of the feeder due to DC bipolar blocking fault, a converter bus reactive power allocation capacity optimization scheme is proposed with the constraint that the transient ...
Xinyue LI   +4 more
doaj   +1 more source

Zero‐Current Switching Based Model Predictive Control of a Double‐Extended Overlapped Alternate Arm Converter Used in the VSC–HVDC System

open access: yesHigh Voltage, EarlyView.
ABSTRACT The alternate arm converter (AAC) is one of the most efficient multilevel topologies based on voltage source converters (VSCs), which has recently gained attention in various applications, particularly in high voltage direct current (HVDC) systems.
Ehsan Akbari, Milad Samady Shadlu
wiley   +1 more source

Lightning caused overvoltages on power transformers recorded by on-line transient overvoltage monitoring system [PDF]

open access: yes, 2018
Transient overvoltages generated by lightning strikes or switching operations represent a significant risk to bushings and windings of power transformers.
Keitoue, Samir   +5 more
core   +1 more source

Review of overhead line defect inspection based on deep learning and UAV images

open access: yes电力工程技术
Line commutated converter based high voltage direct current (LCC-HVDC) is the key to large-scale grid connection and long-distance transmission of renewable energy. However, faults such as DC blocking and commutation failure may lead to short-term excess
ZHOU Wenqing, LIU Gang
doaj   +1 more source

Infeasibility Analysis of Half-Wavelength Transmission Systems

open access: yesEnergies, 2018
This paper analyzes the infeasibility of half-wavelength transmission systems in the aspects of power-frequency overvoltage and synchronization stability. The circuit model of the long-distance transmission system is established at first for steady-state
Zheng Xu, Jian Yang, Nengjin Sheng
doaj   +1 more source

Comprehensive Design and Experimental Validation of 30 kV Ultra‐Fast Flexible Controllable Arresters for HVDC Systems

open access: yesHigh Voltage, EarlyView.
ABSTRACT To effectively suppress transient overvoltages in HVDC systems, the design and experimental validation of a multi‐module series controllable arrester are presented. The voltage‐limiting performance, series voltage equalisation capability, and robustness under fault conditions in high‐voltage scenarios require further research.
Tai Yang   +4 more
wiley   +1 more source

Home - About - Disclaimer - Privacy