Results 31 to 40 of about 892 (179)

Evaluation Methodology, Numerical Verification and Retrofilling Procedure for Power Transformers to Ensure K‐Class Flame Retardancy and Environmentally Friendly

open access: yesHigh Voltage, EarlyView.
ABSTRACT With increasing demands for fire safety and environmental friendliness, retrofilling transformers with alternative insulating liquids has become a growing trend. However, retrofilling power transformers remains uncertain, as more residual mineral oil compromises K‐class flame retardancy, and its impact on environmental performance has yet to ...
Zhenfu Tang   +5 more
wiley   +1 more source

Coordinated optimization of control parameters for suppressing transient overvoltage in wind power DC transmission systems

open access: yesFrontiers in Energy Research
With the increasing proportion of new energy in power systems, the instability issues of novel power systems become more prominent. This paper addresses the transient overvoltage problem in wind power DC transmission systems by proposing a method for ...
Jie Zhao   +6 more
doaj   +1 more source

Research on over-voltage characteristics of ultra high-voltage direct current transmission system

open access: yesEnergy Reports, 2022
Load dumping overvoltage has a significant effect on insulation coordination of direct current (DC) transmission system. Based on the PSCAD/EMTDC electromagnetic transient simulation programs, this paper has built the electromagnetic transient ...
Yingjin Li   +6 more
doaj   +1 more source

Arc Resistance Enhancement of Converter Transformer Tank Through Structural Improvements: Simulation and Experimental Validation

open access: yesHigh Voltage, EarlyView.
ABSTRACT Currently, limited research exists on the structural response and protection methods of the converter transformer tank for ± 800 kV ultra‐high voltage direct current transmission project to high energy arc faults. This research investigates the dynamic response and the vulnerable areas of the ultra‐high voltage converter transformer under the ...
Ke Wang   +5 more
wiley   +1 more source

Research on the impact of grid-connected offshore wind farms on transient overvoltage and characteristics of harmonic resonances

open access: yesZhejiang dianli, 2023
Grid-connected offshore wind farms are likely to cause harmonic resonances in the power system that jeopardize the safe operation of the power grid. To this end, the impact of grid-connected offshore wind farms on the transient overvoltage and harmonic ...
XU Qunwei   +6 more
doaj   +1 more source

Rare Lightning and Convection Characteristics During Two Successive Tornadoes in Southern China

open access: yesHigh Voltage, EarlyView.
ABSTRACT Systematic investigations into lightning characteristics of tornado storms in China remain scarce. This study comprehensively analyses rare lightning behaviour and overshooting top characteristics for two successive tornadoes during a long‐lived supercell in southern China on 27 April 2024.
Fengquan Li   +9 more
wiley   +1 more source

Research on Transient Overvoltage Characteristics and Mapping Relationships of Photovoltaic/PMSG Under Electromagnetic/Electromechanical Models

open access: yesIET Renewable Power Generation
As the ‘dual carbon’ goals continue to advance in China, the grid‐connected scale of new energy power generation equipment such as wind power and photovoltaic power is constantly increasing.
Shiyun Xu   +4 more
doaj   +1 more source

Mechanism of Quasi‐Power‐Frequency Resonant Overvoltage Triggered by Multiple Lightning Strikes in High‐Voltage Alternating Current Systems Equipped With Shunt Reactor

open access: yesHigh Voltage, EarlyView.
ABSTRACT This paper investigates the generation mechanism of quasi‐power‐frequency resonant overvoltage triggered by multiple lightning strikes in high‐voltage alternating current (HVAC) systems equipped with shunt reactors. Based on field measurements from a 500 kV AC system, equivalent and simplified circuit models have been established to analyse ...
Tao Liang   +7 more
wiley   +1 more source

Research on transient AC overvoltage suppression method of DC sending end based on novel fast-excitation MCR

open access: yesInternational Journal of Electrical Power & Energy Systems
The growing reliance on high-power high-voltage direct current (HVDC) transmission systems has intensified challenges associated with transient AC overvoltage induced by commutation failures resulting from converter operation characteristics.
Xiyu Yin   +6 more
doaj   +1 more source

Modelling and identification for reduction of overvoltage transients

open access: yesIEE Proceedings - Electric Power Applications, 2003
The main problems that appear when using a long cable connection between a Variable Frequency Drive (VFD) and the AC motor are over-voltages and bearing currents. The last one concerns especially EMC, while the over-voltage transients can be fatal to the motor.
Capitaneanu, Stefan   +4 more
openaire   +3 more sources

Home - About - Disclaimer - Privacy