Results 71 to 80 of about 420,105 (198)
Analysis of submodule overvoltage mechanism and suppression strategy for DC chopper
Abstract In flexible DC transmission systems, when a fault occurs in the receiving-end AC system, it results in a power surplus on the receiving-end DC side. This necessitates a dynamic active power balancing device, leading to the emergence of the DC chopper in this context.
Xue Bai +6 more
openaire +1 more source
The rapid deployment of both line-commutated converter-based high-voltage direct current (LCC-HVDC) and voltage source converter-based high-voltage direct current (VSC-HVDC) does not only prolificate AC/DC grid coupling but also form new DC transmission ...
Yi Hao +4 more
doaj +1 more source
Evaluation of the efficacy of transient overvoltages suppression measures in different wind farm topologies using SF6 circuit breaker. [PDF]
Eliyan T, Wadie F.
europepmc +1 more source
In a high-voltage direct current (HVDC) transmission system, commutation failure at the receiving end may lead to transient overvoltage at the sending end converter bus of the weak alterative current (AC) system. Firstly, the principle calculation method
Peng Shi +7 more
core +1 more source
At present, the related research on the internal overvoltage of the power collection system is mostly about the offshore wind farms connected to the grid through high voltage AC transmission lines, but the far-offshore wind farms that are connected to ...
Wenjing CHENG, Ru'an DING, Tiebing LU
doaj +1 more source
Protection against lightning and overvoltage
Tato bakalářská práce se zabývá ochranou technických prostředků pro ochranu majetku před bleskem a přepětím. V práci jsou uvedeny legislativní podmínky pro použití přepěťových ochran.
Horák, Martin
core +2 more sources
With the large-scale deployment of renewable energy, transmission systems for new energy sources are increasingly exposed to transient overvoltage issues induced by DC blockages and commutation failures. To address the challenges of an imprecise response
Shuqin Sun +6 more
doaj +1 more source
Passive filters are conventionally used to suppress overvoltage in the motor terminal, either by reducing the voltage rising rate at the inverter output, or by decreasing the motor terminal impedance.
Lee, S, Nam, K
core +1 more source
With the rapid development of DC grids, resonant DC circuit breakers (RDCBs) have become critical for fault isolation. However, existing RDCBs often suffer from severe energy mismatches, and components, including mechanical switches, resonant capacitors,
Zhicheng Zhang +4 more
core +1 more source
Commutation failures in line commuted converter-based high voltage direct current (LCC-HVDC) transmission systems leads to an increase in the converter bus voltage of the rectifier station, thus resulting in AC transient overvoltage in the sending-end ...
Yujie Chen +3 more
core +1 more source

