Results 91 to 100 of about 32,486 (240)

Initial dynamics of the EKG during an electrical defibrillation of the heart [PDF]

open access: yes
In tests on 11 mature dogs, immobilized by means of an automatic blocking and synchronization system, artefact free EKG were obtained, beginning 0.04-0.06 sec after passage of a defibrillating current. Different versions of the start of fibrillation were
Bikov, I. I.   +2 more
core   +1 more source

Emerging Triboelectric Nanogenerators for In‐Body Implantation

open access: yesSmall Methods, EarlyView.
This review explores functional implantable triboelectric nanogenerators in biomedical applications, discussing their mechanisms, electricity generation, and design approaches. To solve postimplantation challenges, four types of triboelectric nanogenerators (TENGs) are introduced: stretchable, bioadhesive, on‐demand biodegradable, and multiresponsive ...
Xiao Xiao   +4 more
wiley   +1 more source

Epidemiological Record of Permanent Artificial Cardiac Pacemaker Implant at a Reference Center

open access: yesJournal of Cardiac Arrhythmias, 2020
Objective: To identify the profile of patients who implanted pacemakers and their complications in a tertiary cardiology center in the state of Santa Catarina.
Larissa Freitas Nunes Goldoni   +4 more
doaj   +4 more sources

Comparison of Benefits from Cardiac Resynchronization Therapy between Patients with Ischemic Cardiomyopathy and Patients with Idiopathic Dilated Cardiomyopathy [PDF]

open access: yesJournal of Tehran University Heart Center, 2009
Background: Cardiac resynchronization therapy (CRT) is an effective treatment for patients with moderate to severe heart failure. However, 20-30% of patients remain non-responders to CRT.
Talia Alenabi   +15 more
doaj   +2 more sources

Synchronization interfaces and overlapping communities in complex networks

open access: yes, 2008
We show that a complex network of phase oscillators may display interfaces between domains (clusters) of synchronized oscillations. The emergence and dynamics of these interfaces are studied in the general framework of interacting phase oscillators ...
D. Li   +9 more
core   +1 more source

Multiscale Engineering of Ion‐Conducting Gels for Sustainable Bioelectronic Systems

open access: yesSmall Methods, EarlyView.
This review highlights multiscale engineering strategies for ion‐conducting gels aimed at achieving sustainable bioelectronic systems. It systematically examines material‐level, device‐level, and system‐level approaches to ensure long‐term stability and functional integrity under physiological conditions, integrating molecular design, device ...
Ji Hong Kim   +6 more
wiley   +1 more source

The neurochemical basis of photic entrainment of the circadian pacemaker [PDF]

open access: yes
Circadian rhythmicity in mammals is controlled by the action of a light-entrainable hypothalamus, in association with two cell clusters known as the supra chiasmatic nuclei (SCN).
Buckley, Becky   +2 more
core   +1 more source

Integrative Approach - New Level Knowledge of Functions: Opportunities and Prospects [PDF]

open access: yes, 2012
In this article, the example of the mechanisms of heart rhythmogenesis in the intact organism is used to demonstrate the new capabilities provided by an integrative approach. It is shown that the rhythm is formed in the brain, transmitted to the heart in
Vladimir M. Pokrovskii
core   +1 more source

Differences and Commonalities of Electrical Stimulation Paradigms After Central Paralysis and Amputation

open access: yesArtificial Organs, EarlyView.
Invasive and non‐invasive functional electrical stimulation (FES) is a well‐established method to partially restore function after paralysis and deliver sensory feedback after amputation. This work summarizes the current state‐of‐the‐art of FES for restoring function, supporting rehabilitation therapy, and assistive devices.
Thomas Stieglitz   +3 more
wiley   +1 more source

Problems of artificial pacemaker therapy.

open access: yesJapanese Circulation Journal, 1985
Four hundred and sixty-seven cases with implantation of an artificial pacemaker were studied. The postoperative survival rate was 63% for 15 years. Seventy-two percent of type III patients of the sick sinus syndrome were free from postoperative thromboembolism and the lowest of the three types of the sick sinus syndrome.
M, Murase   +7 more
openaire   +3 more sources