Results 51 to 60 of about 663,071 (359)
A coordination polymer [Pb(tadt)]n prepared by a microwave‐assisted solvothermal method selectively reduces CO2 into formate under visible light with a high apparent quantum yield of ≈25% at 400 nm. It can function as a pre‐catalyst, along with conductive Ketjen Black, to form an active PbCO3/Pb3(CO3)2(OH)2 mixture that exhibits a high Faradaic ...
Chomponoot Suppaso+8 more
wiley +1 more source
SP-Sephadex equilibrium chromatography of bradykinin and related peptides: Application to trypsin-treated human plasma [PDF]
An analytical method is deseribed for the separation of bradykinin, Lys-bradykinin, and Met-Lys-bradykinin by equilibrium chromatography on SP-Sephadex C-25 eluted in 0.02 Tris-HCl buffer, pH 8.10, 0.12 NaCl.
Camargo, Antonio C. M.+4 more
core +1 more source
Thermally Induced Gelling Systems Based on Patchy Polymeric Micelles
A novel strategy to design thermally induced gelling systems with tunable material properties is reported. Polymeric mixed‐shell micelles displaying multiple thermosensitive patchy domains formed hydrogels by assembling into well‐entangled worm‐like network structures upon heating to body temperature. The patchy micelle design significantly affects the
Binru Han+9 more
wiley +1 more source
Compendio bibliográfico sobre cromatografía líquida de alta eficacia de lípidos: IV 1985-1994.
The present summary, following the tradition begun by K. Aitzetmüller with the works published from 1961 and continued by the present authors from 1975, is a compilation of articles appearing between the years given in the title; the database used was ...
E. Graciani Constante+2 more
doaj +1 more source
Combined pyrolysis and radiochemical gas chromatography for studying the thermal degradation of polymers [PDF]
Pyrolysis gas chromatography and radioactive tracer techniques have been used independently to study the thermal degradation of polymers. In these laboratories the two techniques have been combined to elucidate some of the mechanisms of the thermal ...
Bishop, D. P.+2 more
core
Facilitating insight into a simulation model using visualization and dynamic model previews [PDF]
This paper shows how model simplification, by replacing iterative steps with unitary predictive equations, can enable dynamic interaction with a complex simulation process.
Cribbin, T, de Folter, J
core +1 more source
This study introduces a paper‐based biodegradable, humidity‐insensitive e‐nose for real‐time breath analysis, addressing challenges in existing technologies such as humidity interference, high costs, and environmental impact. Featuring hydrophobic polymer coatings, these sensors reliably detect VOCs even in high‐moisture environments.
Indrajit Mondal+2 more
wiley +1 more source
Determination of Radiochemical Purity of 99mTc-DTPA Using One-System Method of Paper Chromatography [PDF]
The more efficient and effective quality control techniques for 99mTc-DTPA are needed because 99mTc has a short half-life of around 6.0 hours. We have succeeded in developing a one-system of TLC for radiochemical purity testing system that is faster and ...
Maskur Maskur+7 more
doaj
Breath analysis is considered to be an effective method for point-of-care diagnosis due to its noninvasiveness, quickness and simplicity. Gas sensors for breath analysis require detection of low-concentration substances.
Masanobu Motooka, Shigeyasu Uno
doaj +1 more source
Complete gradient-LC-ESI system on a chip for protein analysis [PDF]
This paper presents the first fully integrated gradient-elution liquid chromatography-electrospray ionization (LC-ESI) system on a chip. This chip integrates a pair of high-pressure gradient pumps, a sample injection pump, a passive mixer, a packed ...
Lee, T. D.+3 more
core