Optimal Oversizing Index Depending on Valve Type and Leakage-Proof Function for Preventing Paravalvular Leakage after Transcatheter Aortic Valve Implantation [PDF]
Paravalvular leak (PVL) is an important complication of transcatheter aortic valve implantation (TAVI) and is associated with poor prognosis. We aimed to identify the risk factors for PVL after TAVI including patient (calcium amount or location), device (
Jung-Kyu Han, Han Mo Yang, Hak Seung Lee
exaly +3 more sources
A fast in silico model for preoperative risk assessment of paravalvular leakage. [PDF]
AbstractIn silico simulations can be used to evaluate and optimize the safety, quality, efficacy and applicability of medical devices. Furthermore, in silico modeling is a powerful tool in therapy planning to optimally tailor treatment for each patient.
Spanjaards M +5 more
europepmc +6 more sources
Prediction of paravalvular leakage after transcatheter aortic valve implantation. [PDF]
Significant paravalvular leakage (PVL) after transcatheter aortic valve implantation (TAVI) is related to patient mortality. Predicting the development of PVL has focused on computed tomography (CT) derived variables but literature targeting CoreValve devices is limited, controversial, and did not make use of standardized echocardiographic methods. The
Di Martino LF +8 more
europepmc +8 more sources
Paravalvular leakage following surgical valve replacement is one of the major complications that have long-term morbidity. The gold standard of treatment was surgery in most literature, but transcatheter procedures showed promising results.
Ehsan Khalilipur +3 more
doaj +2 more sources
Evaluation of Paravalvular Leakage in Novel Mechanical Heart Valve
We developed a new mechanical heart valve prototype with a unique mechanism for attachment to cardiac tissue. The development of novel prosthetic heart valve systems requires careful assessment of paravalvular leaks — leakage of fluid that takes place between the valve and the cardiac tissue it is attached to.
Ankit Saxena +4 more
openaire +2 more sources
Wavelet analysis of mechanical heart valve sounds with paravalvular leakage [PDF]
International Conference on Computer Technologies in Physical and Engineering Applications (ICCTPEA) -- JUN 30-JUL 04, 2014 -- Saint Petersburg, RUSSIADiscrete wavelet transform has been proposed for the diagnosis of paravalvular leakage(PVL) occurs ...
Sabri Altunkaya +2 more
openaire +2 more sources
The fifth redo operation for mitral paravalvular leakage and free-floating closure device extraction: A case report [PDF]
Yavuz Sensoz, Mehmet Eren, Yasin Ozden
exaly +2 more sources
The Lotus dilemma-respond to paravalvular leakage, but not answering pacemaker implantations? [PDF]
The treatment of symptomatic aortic valve stenosis has been revolutionized by transcatheter aortic valve replacement (TAVR), evolving from a last resort therapy to the standard treatment of patients at intermediate or high risk for conventional surgery (1,2).
Pellegrini C, Hengstenberg C, Husser O.
europepmc +4 more sources
Background: Optimal valve sizing provides improved results in transcatheter aortic valve replacement. Operators hesitate about the valve size when the annulus measurements fall into borderline area.
Erkan Yıldırım +13 more
doaj +1 more source
Comparative Evaluation of Suture Techniques in Mitral Valve Replacement: Impact on Clinical Outcomes
Background: This study aimed to compare the outcomes of mitral valve replacement (MVR) using the intermittent simple suture technique versus the horizontal matrix suture technique with pledgeted in terms of paravalvular leakage and infective endocarditis.
Burak Kasapoğlu +4 more
doaj +1 more source