Results 101 to 110 of about 2,395,295 (133)
Some of the next articles are maybe not open access.

Laboratory Calibration of HFCT Partial Discharge Detection Systems

2021 IEEE 4th International Electrical and Energy Conference (CIEEC), 2021
With the advantages of high sensitivity and non-intrusiveness, HFCT PD detection systems are implemented in order to monitor incipient faults of power cables. This paper introduces a laboratory calibration method for HFCT PD detection systems based on a Gauss pulse signal.
Yifan Wang   +5 more
openaire   +1 more source

Performance Comparison of Various Partial Discharge Calibrators

2024 4th International Conference on Electronic and Electrical Engineering and Intelligent System (ICE3IS)
Umar Khayam
exaly   +2 more sources

Programmable Partial Discharge Calibrator Based on Current Source

2025 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)
Jan Hlaváček, Radek Procházka
exaly   +2 more sources

Inverted diagram of calibration for partial discharge measuring

2008 International Conference on Condition Monitoring and Diagnosis, 2008
PD measurement is well-known method for inspection of high voltage equipment. However, its on-site application has some difficulties. This paper is dedicated to the calibration of PD measurement by electrical method; it is more precise, to the method of the introduction of charge into the tested object.
A. Ovsyannikov, S. Zhivodernikov
openaire   +1 more source

Evaluation Of Partial Discharge Measurement Circuits And Associated Calibration Techniques

IEEE Transactions on Power Apparatus and Systems, 1985
This paper presents an evaluation of the RIV circuits used for the measurement of partial discharges. The results show that the NEMA 107-1964 RIV circuit, as presently used in high voltage laboratories, does not consider the entire calibration problem.
S. J. Huang   +3 more
openaire   +1 more source

A critique of present calibration procedures for partial discharge measurements

IEEE Transactions on Electrical Insulation, 1993
The need for improved standardization procedures for use on different types of partial discharge (PD) measuring systems is discussed. This requirement is examined using recording and processing data of complex PD signals obtained from in-service electrical apparatus.
W.S. Zaengl, K. Lehmann
openaire   +1 more source

A Practical Approach for the Calibration of Partial Discharges Measurements at Field

2018 IEEE/PES Transmission and Distribution Conference and Exposition (T&D), 2018
Partial discharges (PD) measurements at field are a useful tool for predictive maintenance of high voltage equipment for preventing in service failures. This paper shows a practical procedure for the calibration of partial discharges measurements at field, when high frequency current transformers (HFCT) installed in equipments' grounding conductors ...
Hedio Tatizawa   +5 more
openaire   +1 more source

On-line partial discharge calibration and monitoring for power transformers

Electric Power Systems Research, 1999
Partial discharge (PD) is one of the major factors causing insulation damage of power transformers. This paper describes the development of on-line partial discharge monitoring system for transformers. The developed set can monitor up to four power transformers continuously.
A.S Farag   +8 more
openaire   +1 more source

Calibration of Partial Discharge Detectors for Pulse-Height Distribution Analysis

IEEE Transactions on Electrical Insulation, 1979
The effect of the calibration-pulse fall times, ranging from 0.52-56 ?s, on the response of partial-discharge detectors using a multichannel analyser has been investigated. Although the equalization of fall/rise time ratio results in a single peak distribution, the latter is sensitive to small variations in this ratio.
Abobakr S. Ahmed, Asser A. Zaky
openaire   +1 more source

Towards improved calibration in the measurement of partial discharges in rotating machinery

IEEE International Symposium on Electrical Insulation, 2002
It is pointed out that an improved calibration strategy for partial-discharge (PD) detectors in rotating machine applications can only be achieved if the propagation characteristics of PD pulses are clearly understood, thus enabling the calibration pulse to simulate the discharge pulse more accurately as it appears at the detector terminals.
R. Geary   +3 more
openaire   +1 more source

Home - About - Disclaimer - Privacy