Targeted radioligand therapy: physics and biology, internal dosimetry and other practical aspects during <sup>177</sup>Lu/<sup>225</sup>Ac treatment in neuroendocrine tumors and metastatic prostate cancer. [PDF]
Dadgar H +31 more
europepmc +1 more source
Related searches:
Development and Application of a Programmable Partial Discharge Calibrator
IEEE Transactions on Instrumentation and Measurement, 2009A programmable partial discharge (PD) calibrator composed of an arbitrary waveform generator that is series connected to a capacitor is described. The voltage waveform supplied by the generator is software controlled. The characteristics and capabilities of the calibrator are presented, and the procedures used for its characterization are discussed ...
Gabriella Crotti +2 more
exaly +3 more sources
Application of a Programmable Partial Discharge Calibrator
Applied Mechanics and Materials, 2014This paper presents the application of a programmable partial discharge calibrator, which used to test the performance of four partial discharge measuring systems by injecting a program controlled known charge sequence into the device under test. Performance of linearity, response to opposite polarity pulses, pulse resolution time and response to ...
Wei Dong Zhang, Zhang Wei Dong
exaly +2 more sources
Study on the calibration of partial discharge calibrator
2008 Conference on Precision Electromagnetic Measurements Digest, 2008The calibration of apparent charge, which can be traced to AC voltage and capacitance, for partial discharge(PD) calibrator is discussed. The methods of fast sampling measurement of peak-to-peak amplitude for step voltage by digital multimeter and the arithmetic in the automatic measurement of apparent charge by digital oscilloscope are focused on ...
null Liu Na +2 more
exaly +2 more sources
Miniature partial discharge calibrator synchronized by capacitive coupling
IEEE Transactions on Electrical Insulation, 1992A new partial discharge calibrator is described. The device, suitable to operate in a floating position, generates synchronized pulses at the mains frequency. Synchronization is achieved by capacitive coupling to the mains with a cable wound around the power leads.
exaly +2 more sources
Design of wireless partial discharge digital calibrator based on LoRa
2022 41st Chinese Control Conference (CCC), 2022Daokai Wu, Xiaojun Wang, Chuxuan Huang
exaly +2 more sources
Performance Comparison of Various Partial Discharge Calibrators
2024 4th International Conference on Electronic and Electrical Engineering and Intelligent System (ICE3IS)Umar Khayam
exaly +2 more sources
A method for calibration of partial discharge calibrators
1998 Conference on Precision Electromagnetic Measurements Digest (Cat. No.98CH36254), 1999A method for calibration of partial discharge calibrators has been developed based on passive integration of the induced charge. The voltage over a known capacitor is measured by a calibrated digital sampling voltmeter and the charge is calculated as the voltage multiplied by the capacitance.
Ove Gunnarsson +2 more
openaire +1 more source
Laboratory Calibration of HFCT Partial Discharge Detection Systems
2021 IEEE 4th International Electrical and Energy Conference (CIEEC), 2021With the advantages of high sensitivity and non-intrusiveness, HFCT PD detection systems are implemented in order to monitor incipient faults of power cables. This paper introduces a laboratory calibration method for HFCT PD detection systems based on a Gauss pulse signal.
Yifan Wang +5 more
openaire +1 more source
Programmable Partial Discharge Calibrator Based on Current Source
2025 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)Jan Hlaváček
exaly +2 more sources