Performance of Reference Partial Discharge Measurement System [PDF]
The work reported here has received support from the EMPIR programme co-financed by the Participating States and from the European Union's Horizon 2020 research and innovation programme.
MEREV, Ahmet +3 more
openaire +3 more sources
Gas-insulated switchgear malfunctions during power system operation may occur due to electrical, thermal, or human errors in the manufacturing process. The leading causes of insulation deterioration of gas-insulated switchgear are discharging along the ...
I-Hua Chung, Yu-Hsun Lin
doaj +1 more source
One of the main tools for monitoring the condition of high voltage equipment is the measurement of partial discharges (PD). The electromagnetic (EM) radiation originated from this degradation phenomenon can be captured by various types of ultra‐high ...
Jorge A. Ardila‐Rey +5 more
doaj +1 more source
Partial discharge (PD) detection is used to evaluate the insulation status of high‐voltage equipment. The most challenging aspect of traditional PD recognition is extracting features from the discharge signal.
Feng‐Chang Gu
doaj +1 more source
Study on the Measurement Technique and Judgment Procedure of Ultrasonic Corona Imaging Equipment
Corona discharge is a phenomenon wherein gas on the surface of electrical equipment is ionised. Severe ionisation can lead to insulation breakdown and cause equipment damage.
Ja-Yoon Kang +4 more
doaj +1 more source
Improvement of partial discharge resistance of polypropylene under AC voltage by blending elastomer
This paper reports on the partial discharge (PD) erosion characteristics of polypropylene (PP)/elastomer blends where ethylene‐octene copolymer elastomer (EOC) and propylene‐based elastomer are involved.
Yu Gao +6 more
doaj +1 more source
Overview and Partial Discharge Analysis of Power Transformers: A Literature Review
The high voltage power transformer is the critical element of the power system, which requires continuous monitoring to prevent sudden catastrophic failures and to ensure an uninterrupted power supply.
Md Rashid Hussain +2 more
doaj +1 more source
Non-Contact High Voltage Measurement in the Online Partial Discharge Monitoring System
The article presents an innovative system for non-contact high voltage (HV) measurement, which extends the measurement capabilities of a portable partial discharges (PD) monitoring system intended for diagnostics of power transformers.
Krzysztof Walczak, Wojciech Sikorski
doaj +1 more source
Partial discharges measurement by UHF method
The unconventional UHF (Ultra High Frequency) method of measuring partial discharges (PD) is based on measuring electromagnetic waves (EM) in the UHF frequency band (300-3000) MHz, using appropriate antennas. This method is unconventional, but is widely accepted due to the possibility of application in plants in the online mode and quick review ...
Malešević Nevena +3 more
openaire +2 more sources
Signal Processing in Partial Discharge Measurement [PDF]
The paper presents traditional analogue and digital techniques in partial discharge measurement. The discharge current pulses are measured from high voltage machin es like power plant generators and transformers. The presented modern digital techniques are suitable for all measurements where impulse energy will be calculated.
Josef Vedral, Martin Kříž
openaire +1 more source