Results 51 to 60 of about 436 (218)

Design and Evaluation of an Integrated Ultra‐High Frequency and Optical Sensor for Partial Discharge Detection in GIS

open access: yesIET Science, Measurement & Technology
Partial discharge (PD) detection is an important technique for monitoring and evaluating the insulation condition of gas‐insulated switchgear (GIS) equipment.
Feng Chen   +5 more
doaj   +1 more source

Partial discharge fault identification of multi-dimensional information sources based on CNN+D-S evidence theory

open access: yes电力工程技术, 2022
The partial discharge fault identification method based on the fusion of multi-dimensional information sources can greatly improve the accuracy and fault tolerance in the fault identification of power equipment.
WANG Lei   +5 more
doaj   +1 more source

Genetic attenuation of ALDH1A1 increases metastatic potential and aggressiveness in colorectal cancer

open access: yesMolecular Oncology, EarlyView.
Aldehyde dehydrogenase 1A1 (ALDH1A1) is a cancer stem cell marker in several malignancies. We established a novel epithelial cell line from rectal adenocarcinoma with unique overexpression of this enzyme. Genetic attenuation of ALDH1A1 led to increased invasive capacity and metastatic potential, the inhibition of proliferation activity, and ultimately ...
Martina Poturnajova   +25 more
wiley   +1 more source

Defects Classification of Hydro Generators in Indonesia by Phase-Resolved Partial Discharge

open access: yesMathematics, 2022
This paper proposed a phase-resolved partial discharge (PRPD) shape method to classify types of defect generator units by using offline partial discharge (PD) measurement instruments.
Chun-Yao Lee   +2 more
doaj   +1 more source

IMPDH inhibition enhances cytarabine efficacy in SAMHD1‐expressing leukaemia cells via guanine nucleotide depletion

open access: yesMolecular Oncology, EarlyView.
Cytarabine is a key therapy for acute myeloid leukaemia (AML), but its efficacy is limited by the dNTPase SAMHD1, which hydrolyses its active metabolite. Screening nucleotide biosynthesis inhibitors revealed that IMPDH inhibitors selectively sensitise SAMHD1‐proficient AML cells to cytarabine.
Miriam Yagüe‐Capilla   +9 more
wiley   +1 more source

In-depth exploration of partial discharge modelling methods within insulations

open access: yesCleaner Engineering and Technology, 2022
Partial discharge (PD) activities are the essential contributor of insulation failure, which constitute more than 60% for damaging high voltage equipment.
Hadi Nabipour Afrouzi   +6 more
doaj   +1 more source

Signal denoising techniques for partial discharge measurements [PDF]

open access: yesIEEE Transactions on Dielectrics and Electrical Insulation, 2005
One of the major challenges of on-site partial discharge (PD) measurements is the recovery of PD signals from a noisy environment. The different sources of noise include thermal or resistor noise added by the measuring circuit, and high-frequency sinusoidal signals that electromagnetically couple from radio broadcasts and/or carrier wave communications.
Sriram, S.   +3 more
openaire   +2 more sources

Keratin 19 as a prognostic marker and contributing factor of metastasis and chemoresistance in high‐grade serous ovarian cancer

open access: yesMolecular Oncology, EarlyView.
Keratin 19 (KRT19) is overexpressed in high‐grade serous ovarian cancer with high levels of Kallikrein‐related peptidases (KLK) 4–7 and is associated with poor survival. In vivo analyses demonstrate that elevated KRT19 increases peritoneal tumour burden.
Sophia Bielesch   +13 more
wiley   +1 more source

Establishment of a humanized patient‐derived xenograft mouse model of high‐grade serous ovarian cancer for preclinical evaluation of combination immunotherapy

open access: yesMolecular Oncology, EarlyView.
We have established a humanized orthotopic patient‐derived xenograft (Hu‐oPDX) mouse model of high‐grade serous ovarian cancer (HGSOC) that recapitulates human tumor–immune interactions. Using combined anti‐PD‐L1/anti‐CD73 immunotherapy, we demonstrate the model's improved biological relevance and enhanced translational value for preclinical ...
Luka Tandaric   +10 more
wiley   +1 more source

Evaluation of Uncertainty in Partial Discharge Measurement: A Case Study

open access: yesIEEE Access
ISO/IEC 17025:2017 recommends all accredited laboratories under this standard, performing testing and calibration, shall identify and evaluate the contributions to the uncertainty of their measurements.
Asif Islam   +5 more
doaj   +1 more source