Partial discharges in HV machines; initial considerations for a PD specification
IEE Proceedings A Science, Measurement and Technology, 1993Partial discharge (PD) specifications exist for all types of electrical equipment except motors and generators. Whereas specifications essentially require that the equipment is discharge-free the stator conductor bar insulation of the motors and generators under consideration is micaceous and has excellent PD resistance.
J.W. Wood +4 more
openaire +1 more source
Experiences in on-site partial discharge measurements and prospects for PD monitoring
2008 International Conference on Condition Monitoring and Diagnosis, 2008With four case studies (dry-type transformer, power transformer, GIS, generator) this paper describes the principle of synchronous multi-channel PD measurements and its benefits for PD data evaluation. With respect to monitoring the tracing of a charge value as QIEC over the measuring time is not sufficient to assess the PD activity of an HV apparatus.
K. Rethmeier +6 more
openaire +1 more source
Partial discharge (PD) measuring techniques
15th IET International School on High Voltage Engineering and Testing 2008, 2008The physical background of partial discharges will be explained on simple models. The requirements on the complete partial discharge measuring systems including the calibration and evaluation of the measuring results will be discussed and examples of partial discharge measurements on transformers in the laboratory and on site will be presented. Finally
openaire +1 more source
PDTools: A toolbox of partial discharge (PD) signal analysis for transformer condition assessment
2017 IEEE Power & Energy Society General Meeting, 2017Partial discharge (PD) measurement of power transformers provides a means for condition assessment of their insulation systems. To reach an informed assessment on the condition of a transformer's insulation system, it needs to appropriately analyze the measured PD signals. Though abundant methods have been proposed for PD signal analysis, it is still a
Ma, Hui +4 more
openaire +2 more sources
Partial discharge. IV. Commercial PD testing
IEEE Electrical Insulation Magazine, 1991For pt.III see ibid., vol.6, no.6, p.11 et seq. (1990). Commercially available partial discharge (PD) detectors are described, along with their important characteristics. The primary characteristics that detectors have in common and that are used as a basis for classification are the number of inputs used, the bandwidth of the detector, and the method ...
openaire +1 more source
Joint time-frequency analysis for partial discharge (PD) signal extraction
2018 12th International Conference on the Properties and Applications of Dielectric Materials (ICPADM), 2018The joint time-frequency analysis has been recently applied to PD signal extraction. Its advantage is widely considered to be the capability of analyzing signals in time and frequency domains at multiple scales. This paper presents a study on recent advances in the application of joint time-frequency analysis techniques to extract PD signal from noise.
Ma, Hui +3 more
openaire +2 more sources
Partial discharge. III. Cavity-induced PD in solid dielectrics
IEEE Electrical Insulation Magazine, 1990For pt.II see ibid., vol.6, no.5, p.35 et seq. (1990). The question of how to relate the magnitude of the measured, effective, partial discharge (PD) to the size, shape, and position of the cavity within a solid dielectric system is addressed. The causes of cavities are examined, and a brief review of gas breakdown is given. It is then shown that for a
openaire +1 more source
Partial discharge. XI. Limitations to PD as a diagnostic for deterioration and remaining life
IEEE Electrical Insulation Magazine, 1992For pt.X see ibid., vol.8, no.1, p.16 (1992). The correlation of partial discharge (PD) measurements with insulation degradation and failure is addressed. The limitations inherent to such diagnostics as applied to solid insulating systems are examined.
C. Laurent, C. Mayoux
openaire +1 more source
Partial Discharge Investigation on Power Cable Termination Using PD Acoustic Detection
2020 International Conference on Power, Energy and Innovations (ICPEI), 2020This paper presents the comparison of partial discharge (PD) interpretation on three different standard test objects and defected power cable terminations among an PD acoustic sensor and conventional IEC60270 capacitive PD detection system. The experiments are conducted as off-line testing which is sourced by isolated high voltage step up transformer ...
Thanapong Suwanasri +7 more
openaire +1 more source
Partial discharge. IX. PD in gas-insulated substations-fundamental considerations
IEEE Electrical Insulation Magazine, 1991For pt.VIII see ibid., vol.7, no.5, p.9 et seq. (1991). The physical aspects of partial discharge (PD) in SF/sub 6/ gas-insulated substations (GIS) are reviewed. The orientation is toward present and developing techniques for evaluating defects in solid and gaseous insulation systems on the basis of PD measurement.
R. Baumgartner +3 more
openaire +1 more source