Results 221 to 230 of about 2,966,124 (288)
Dynamic Severity Assessment of Partial Discharge in HV Bushings Based on the Evolution Characteristics of Dense Clusters in PRPD Patterns. [PDF]
Gao X +6 more
europepmc +1 more source
Using synthetic data for pretraining partial discharge detection in overhead transmission lines. [PDF]
Klein L +4 more
europepmc +1 more source
HER2-mutated lung squamous cell carcinoma responding to trastuzumab deruxtecan followed by pyrotinib: a Case Report. [PDF]
Liu L +5 more
europepmc +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
2016 Biennial International Conference on Power and Energy Systems: Towards Sustainable Energy (PESTSE), 2016
In high voltage (HV) electrical power systems; varieties of materials (solid, liquid and gaseous) are used for insulation purpose to protect the early failure in High Voltage power equipment. Most of insulating materials are not perfect in all respect and contain some impurities.
Devendra Gowda, null Anandraj
openaire +1 more source
In high voltage (HV) electrical power systems; varieties of materials (solid, liquid and gaseous) are used for insulation purpose to protect the early failure in High Voltage power equipment. Most of insulating materials are not perfect in all respect and contain some impurities.
Devendra Gowda, null Anandraj
openaire +1 more source
Partial discharge. VI: PD testing of printed circuit boards
IEEE Electrical Insulation Magazine, 1991For pt.V see ibid., vol.7, no.2, p.28 et seq. (1991). The results of a research program concerned with applying partial-discharge (PD) testing to the nondestructive evaluation of the dielectric characteristics of coated printed circuit board (PCB) systems that must meet the high-voltage dielectric test requirements of low-voltage equipment are reported.
H. Koch +3 more
openaire +1 more source
Partial discharge. VIII. PD testing of solid dielectric cable
IEEE Electrical Insulation Magazine, 1991For pt.VII see ibid., vol.7, no.4, p.9 (1991). The development of solid dielectric cable is discussed and its potential defects are described. Limitations to partial discharge (PD) measurement and testing are discussed, and its use for detecting cavities (also referred to as voids), which are probably the most common defect in solid dielectric cable ...
J.C. Chan +3 more
openaire +1 more source
The correlation between partial discharges (PD) and gassing in insulating liquids
10th International Conference on Conduction and Breakdown in Dielectric Liquids, 2002The authors report on investigations performed to determine the relationship between PD parameters and the dissolved gas generated by partial discharges in mineral-based oil. The PD activity of mineral-based oil is shown to depend upon many parameters, including the influence of the standing time between the filling of the test vessel and the switching
H. Borsi, U. Schroder
openaire +1 more source
Analysis of Internal Partial Discharge Based on PD Current Waveform
2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena, 2008The analysis of partial discharge (PD) phenomenon to cause long-term degradation of electrical insulation systems is essential to development of electrical insulation technology. The PD pattern on the relation between PD magnitude and the phase of applied voltage is well known one of the electrical insulation diagnosis methods for high voltage ...
Kenji Nanao +2 more
openaire +1 more source

