Calibrating the UHF technique of partial discharge detection using a PD simulator
IEEE Transactions on Dielectrics and Electrical Insulation, 1995The paper describes a technique for simulating the presence of partial discharges in gas-insulated substation (GIS) equipment. The technique employs a pulse generator to inject current pulses through a suitable protrusion. The current pulses have similar temporal characteristics to those produced by an actual discharge event, with the added advantage ...
A.G. Sellars, S.J. MacGregor, O. Farish
openaire +1 more source
Partial Discharge Investigation on Power Cable Termination Using PD Acoustic Detection
2020 International Conference on Power, Energy and Innovations (ICPEI), 2020This paper presents the comparison of partial discharge (PD) interpretation on three different standard test objects and defected power cable terminations among an PD acoustic sensor and conventional IEC60270 capacitive PD detection system. The experiments are conducted as off-line testing which is sourced by isolated high voltage step up transformer ...
Thanapong Suwanasri +7 more
openaire +1 more source
The solid-state transformer (SST) was regarded as the ideal power router in the energy Internet. However, the partial discharge (PD) in tightly packed SST is one of the main causes of interturn multilayer insulation premature failure.
Zhihui Li +5 more
semanticscholar +1 more source
Fundamental investigations concerning the behaviour of partial discharges (PD) in dielectric liquids
10th International Conference on Conduction and Breakdown in Dielectric Liquids, 2002The authors report the results of fundamental investigations on the behavior of partial discharges (PDs) in insulating fluids. The shape of PD pulses is recorded with a special measuring system and the characteristics of PD pulses and their dependencies in insulating liquids are determined.
H. Borsi, U. Schroder
openaire +1 more source
Partial discharge. IX. PD in gas-insulated substations-fundamental considerations
IEEE Electrical Insulation Magazine, 1991For pt.VIII see ibid., vol.7, no.5, p.9 et seq. (1991). The physical aspects of partial discharge (PD) in SF/sub 6/ gas-insulated substations (GIS) are reviewed. The orientation is toward present and developing techniques for evaluating defects in solid and gaseous insulation systems on the basis of PD measurement.
R. Baumgartner +3 more
openaire +1 more source
Partial discharge. XI. Limitations to PD as a diagnostic for deterioration and remaining life
IEEE Electrical Insulation Magazine, 1992For pt.X see ibid., vol.8, no.1, p.16 (1992). The correlation of partial discharge (PD) measurements with insulation degradation and failure is addressed. The limitations inherent to such diagnostics as applied to solid insulating systems are examined.
C. Laurent, C. Mayoux
openaire +1 more source
Development of a partial discharge emulator for calibration of a radiometric PD detection system
2012 IEEE International Instrumentation and Measurement Technology Conference Proceedings, 2012A purely electronic partial discharge emulator for use in a location estimation algorithm for online partial discharge detection is proposed as a low-cost approach to real-time condition monitoring, asset management and operation optimization in future smart grid. Some early progress in the development of subsystems (specifically the radiometer antenna
J. M. R. de Souza Neto +5 more
openaire +1 more source
Interference analysis and rejection of partial discharge (PD) monitoring signal on-site
Proceedings of 2001 International Symposium on Electrical Insulating Materials (ISEIM 2001). 2001 Asian Conference on Electrical Insulating Diagnosis (ACEID 2001). 33rd Symposium on Electrical and Electronic Insulating Materials and Applications in System, 2002According to the waveform and spectrum characteristics, various interferences during on-line PD measurement could be divided into three types such as the sinusoidal continuous noises, pulse shaped interference (including the periodical and stochastical) and background noises (similar to the white noise).
null Xiaoning Wang +2 more
openaire +1 more source
Initiation and formation of partial discharges (PD) in mineral based insulating oil
Proceedings of 1993 IEEE 11th International Conference on Conduction and Breakdown in Dielectric Liquids (ICDL '93), 1994This paper reports the results of fundamental investigations concerning the behavior of partial discharges (PD) in mineral-based oil with the aim of characterizing the physical mechanisms that lead to the initiation and formation of PD pulses. First the influence of the parameters temperature, moisture, pressure and oil condition on the PD inception ...
H. Borsi, U. Schroder
openaire +1 more source
Model for partial discharges associated with treeing breakdown: I. PDs in tree channels
Journal of Physics D: Applied Physics, 2000In order to check our physical model for partial discharges (PDs) in a tree channel, the light emission from a PD in an actual tree was observed. The experimental results agreed with the model. By using the model, conditions for the formation of typical phase-amplitude-number (-q-n) pattern of PDs from treeing was discussed.
Kai Wu +3 more
openaire +1 more source