Results 31 to 40 of about 24,806 (164)

Performance Evaluation of Outdoor High Voltage Glass Insulators in High Pollution Industrial Areas Using Simulated Acid Rain Contamination

open access: yesIEEE Access, 2022
A suitable, non-standard method for artificial pollution testing using simulated acid rain pollution in a laboratory was developed in this work. The method is applicable to a wide range of climatic conditions and rain acidities.
Chibuike Ilomuanya   +2 more
doaj   +1 more source

Classification of partial discharges

open access: yesIEEE Transactions on Electrical Insulation, 1993
For a long time, classification of partial discharges was performed by eye, by studying discharge patterns at the ellipse of an oscilloscope screen. The introduction of digital processing techniques allowed automation of the recognition procedure. These procedures are reported and applied to a number of actual HV constructions which suffer from partial
Kreuger, F.H. (author)   +2 more
openaire   +3 more sources

Statistical Analysis of Partial Discharge Characteristics in Transformer Oil at the “Point-Plane” Electrode at Alternating Voltage [PDF]

open access: yesProblems of the Regional Energetics, 2017
In this paper, we consider the problems related to measuring and analyzing the characteristics of partial discharges which are the main instrument for oil-filled high-voltage electrical equipment diagnosing.
Korobeynikov S.M.   +3 more
doaj  

Comparative Tests of Partial Discharges in Nomex® 910 Paper and Cellulose Paper

open access: yesEnergies, 2020
The article presents the results of comparative investigations of partial discharges in two insulation systems; aramid-enhanced cellulose paper-mineral oil, and pure cellulose paper-mineral oil. Partial discharges were investigated in a diagonal electric
Hubert Moranda   +4 more
doaj   +1 more source

A Study of the Cleansing Effect of Precipitation and Wind on Polluted Outdoor High Voltage Glass Cap and Pin Insulator

open access: yesIEEE Access, 2022
In this work, the extent of natural cleansing effect of rainfall, wind and fog or a combination of these on an insulator string were investigated. Results showed that pollution losses progress with time, with a considerable fraction of losses occurring ...
Chibuike Ilomuanya   +2 more
doaj   +1 more source

Diagnosis of High Voltage Insulators Made of Ceramic Using Spectrophotometry

open access: yesJournal of Spectroscopy, 2016
The paper presents results of comparative analysis of optical signals emitted by partial discharges occurring on three types of high voltage insulators made of porcelain.
Paweł Frącz   +3 more
doaj   +1 more source

Features of monitoring extra large partial discharge in high voltage insulators

open access: yesИзвестия высших учебных заведений: Проблемы энергетики, 2022
THE PURPOSE of the described study is to study the effect of partial discharges on the physical state of previously detected defects in high-voltage insulators.
D. A. Ivanov
doaj   +1 more source

Partial discharge pulse propagation in power cable and partial discharge monitoring system [PDF]

open access: yesIEEE Transactions on Dielectrics and Electrical Insulation, 2014
Partial discharge (PD) based condition monitoring has been widely applied to power cables. However, difficulties in interpretation of measurement results (location and criticality) remain to be tackled. This paper aims to develop further knowledge in PD signal propagation in power cables and attenuation by the PD monitoring system devices to address ...
Sheng, Bojie   +6 more
openaire   +3 more sources

IDENTIFICATION OF TECHNOLOGICAL DEFECTS IN HIGH-VOLTAGE SOLID INSULATION OF ELECTRICAL INSULATION STRUCTURES ON THE CHARACTERISTICS OF PARTIAL DISCHARGES

open access: yesElectrical engineering & Electromechanics, 2019
Introduction. High-voltage insulation systems always have some background level of the partial discharges, which does not have any significant effect on the life of the electrical insulation design.
G. V. Bezprozvannych   +3 more
doaj   +1 more source

Partial Discharge Imaging Correlated with Phase-Resolved Patterns in Non-Uniform Electric Fields with Various Dielectric Barrier Materials

open access: yesEnergies, 2020
This paper describes a correlation of partial discharge phase-resolved patterns with an optical imaging performed in a non-uniform electric field configuration.
Marek Florkowski   +3 more
doaj   +1 more source

Home - About - Disclaimer - Privacy