Development and application of a programmable PD calibrator
2008 Conference on Precision Electromagnetic Measurements Digest, 2008A programmable partial discharge calibrator is described, which is constituted by an arbitrary waveform generator series connected to a capacitor. The step voltage waveform supplied by the generator is software controlled. The characteristics and the capabilities of the calibrator are presented and the procedures adopted for its characterization are ...
M. Chiampi, G. Crotti, Y. Hu, A. Sardi
openaire +1 more source
New approach to calibration in PD measurements
IMTC/99. Proceedings of the 16th IEEE Instrumentation and Measurement Technology Conference (Cat. No.99CH36309), 2003Two different PD measurement instruments could detect different PD values on the same test object even if the measurement conditions are identical. This result is due to the quasi integration error presents in classical PD measurement systems. In this paper the quasi integration error is investigated and two parameters are proposed to qualify the PD ...
E. Carminati, M. Lazzaroni
openaire +1 more source
PD apparent charge estimation and calibration: A critical review
IEEE Transactions on Dielectrics and Electrical Insulation, 2010This paper focuses on the limits of partial discharge apparent charge estimation and calibration using an unified approach. The fundamental problems that prevent accurate apparent charge estimates (resonances, attenuation and partial discharge pulse splitting) are tackled through this approach, highlighting the physical limitations that prevent partial
CAVALLINI, ANDREA +2 more
openaire +1 more source
Calibration of Pd-porphyrin phosphorescence for oxygen concentration measurements in vivo
Journal of Applied Physiology, 1996Sinaasappel, M., and C. Ince. Calibration of Pd-porphyrin phosphorescence for oxygen concentration measurements in vivo. J. Appl. Physiol. 81(5): 2297–2303, 1996.—Quantitative measurement of oxygen concentrations in the microvasculature is of prime importance in issues related to oxygen transport to tissue.
Sinaasappel, M., Ince, C.
openaire +3 more sources
Preparation and calibration of ultrathin Zn layers on Pd(111)
Applied Surface Science, 2009Abstract The general assumption that metal vapors stick at any surface with probability one at room temperature is a necessary requirement for the correct metal deposition rate determination by quartz microbalance measurements. In a combined thermal desorption spectroscopy (TDS) and Auger electron spectroscopy (AES) study on clean and sulphur covered
M. Kratzer +4 more
openaire +1 more source
Investigation of Pd–C cells to improve thermocouple calibration
Metrologia, 2011An intercomparison of the melting temperatures of four Pd–C eutectic fixed-point cells was performed using four Pt/Pd thermocouples. The cells are designed for the calibration of thermocouples and were constructed in the participating laboratories of NPL, LNE, NMIJ and PTB. The measurements were performed in four different high-temperature furnaces but
J V Pearce +5 more
openaire +1 more source
Computation of PD calibration reflectograms in shielded power cable
IEEE Transactions on Dielectrics and Electrical Insulation, 2008The basis for computing PD calibration reflectograms in shielded power cable is presented. The computed reflectograms include the effects of cable attenuation, initial pulse width, cable length, and PD detection bandwidth. The authors have developed a program based on the algorithms presented in this paper which they are making freely available to the ...
Naima Oussalah, Steven Boggs
openaire +1 more source
Influence quantities in the calibration of PD calibrators contribution to the uncertainty estimate
11th International Symposium on High-Voltage Engineering (ISH 99), 1999The numerical integration of the current pulse delivered from a PD calibrator is the easiest way to carry out a performance test of the calibrator itself by using readily available experimental apparatus. The paper discusses the role and the relative importance of the various influence quantities which intervene in the measurement and can contribute to
openaire +1 more source
On the Use of the Co–C Fixed Point for Calibration of Pt/Pd Thermocouples
International Journal of Thermophysics, 2008At INRIM, different Co–C fixed-point cells have been constructed and investigated. Two cells of different design and volume and filled with highly pure cobalt (99.998%) were used to extend the fixed-point calibration of five Pt/Pd thermocouples that had been previously calibrated at the triple point of water and at the fixed points of In, Sn, Zn, Al ...
ASTRUA, MILENA +2 more
openaire +2 more sources
The effectiveness assessment of calibration and measurement of PD apparent charge quantity
2013 IEEE Electrical Insulation Conference (EIC), 2013In the Partial Discharge (PD) measurement on transformer, the discharge quantity is calculated from the offline calibration. The calibrating waveform is standardized by IEC 60270:2000 with a rise time 6 MHz. But the PD measuring instruments in use are standardized by the same document with an up-band frequency less than 500 kHz. Most of the energy is
Hongjing Liu +8 more
openaire +1 more source