Calibration of Pd-porphyrin phosphorescence for oxygen concentration measurements in vivo

Journal of Applied Physiology, 1996
Sinaasappel, M., and C. Ince. Calibration of Pd-porphyrin phosphorescence for oxygen concentration measurements in vivo. J. Appl. Physiol. 81(5): 2297–2303, 1996.—Quantitative measurement of oxygen concentrations in the microvasculature is of prime importance in issues related to oxygen transport to tissue.
Sinaasappel, M., Ince, C.
openaire   +3 more sources

Preparation and calibration of ultrathin Zn layers on Pd(111)

Applied Surface Science, 2009
Abstract The general assumption that metal vapors stick at any surface with probability one at room temperature is a necessary requirement for the correct metal deposition rate determination by quartz microbalance measurements. In a combined thermal desorption spectroscopy (TDS) and Auger electron spectroscopy (AES) study on clean and sulphur covered
M. Kratzer   +4 more
openaire   +1 more source

Investigation of Pd–C cells to improve thermocouple calibration

Metrologia, 2011
An intercomparison of the melting temperatures of four Pd–C eutectic fixed-point cells was performed using four Pt/Pd thermocouples. The cells are designed for the calibration of thermocouples and were constructed in the participating laboratories of NPL, LNE, NMIJ and PTB. The measurements were performed in four different high-temperature furnaces but
J V Pearce   +5 more
openaire   +1 more source

Computation of PD calibration reflectograms in shielded power cable

IEEE Transactions on Dielectrics and Electrical Insulation, 2008
The basis for computing PD calibration reflectograms in shielded power cable is presented. The computed reflectograms include the effects of cable attenuation, initial pulse width, cable length, and PD detection bandwidth. The authors have developed a program based on the algorithms presented in this paper which they are making freely available to the ...
Naima Oussalah, Steven Boggs
openaire   +1 more source

Influence quantities in the calibration of PD calibrators contribution to the uncertainty estimate

11th International Symposium on High-Voltage Engineering (ISH 99), 1999
The numerical integration of the current pulse delivered from a PD calibrator is the easiest way to carry out a performance test of the calibrator itself by using readily available experimental apparatus. The paper discusses the role and the relative importance of the various influence quantities which intervene in the measurement and can contribute to
openaire   +1 more source

On the Use of the Co–C Fixed Point for Calibration of Pt/Pd Thermocouples

International Journal of Thermophysics, 2008
At INRIM, different Co–C fixed-point cells have been constructed and investigated. Two cells of different design and volume and filled with highly pure cobalt (99.998%) were used to extend the fixed-point calibration of five Pt/Pd thermocouples that had been previously calibrated at the triple point of water and at the fixed points of In, Sn, Zn, Al ...
ASTRUA, MILENA   +2 more
openaire   +2 more sources

A novel calibration method for PD measurements in power cables and joints using capacitive couplers [PDF]

open access: possibleMeasurement Science and Technology, 2004
Partial discharge (PD) measurements are universally accepted as a technique giving some indication of the state of the insulation in high-voltage apparatus. Cable end users are keen to adopt online PD monitoring during commissioning of systems. However, because of noisy environments and the problems of interference the conventional methods are ...
Zhong, L, Chen, G, Xu, Y
openaire   +1 more source

The effectiveness assessment of calibration and measurement of PD apparent charge quantity

2013 IEEE Electrical Insulation Conference (EIC), 2013
In the Partial Discharge (PD) measurement on transformer, the discharge quantity is calculated from the offline calibration. The calibrating waveform is standardized by IEC 60270:2000 with a rise time 6 MHz. But the PD measuring instruments in use are standardized by the same document with an up-band frequency less than 500 kHz. Most of the energy is
Hongjing Liu   +8 more
openaire   +1 more source

Calibration of capacitive couplers for online PD detection in HV cables

IEEE Electrical Insulation Magazine, 2005
Possible online quantification and calibration methods for capacitive couplers have been investigated experimentally. The purpose of the calibration is to ensure that if two different systems are used to measure the same sample, they measure the same "apparent PD magnitude," which is the charge transfer at the sample electrodes.
Wang, P., Lewin, P.L., Sutton, S.J.
openaire   +1 more source

Possibility of PD calibration on power transformers using UHF probes

IEEE Transactions on Dielectrics and Electrical Insulation, 2017
Partial Discharge (PD) measurement on power transformers using Ultra-High Frequency (UHF) techniques has great advantages on IEC method including possibility of online application, localization and greater immunity against external noises. But lacking a method to calibrate or at least determine sensitivity of UHF method for power transformers is the ...
H. Jahangir   +3 more
openaire   +1 more source