Probiotic supplementation for anxiety symptoms in people with Parkinson's disease: a randomized, double-blind, placebo-controlled trial. [PDF]
Lam JST +11 more
europepmc +1 more source
Pathogenicity of <i>P. gingivalis</i> strains carrying clusters of specific polymorphic variants of peptidylarginine deiminase gene. [PDF]
Strzelec K +17 more
europepmc +1 more source
Ultrasensitive Protein Aggregate Quantification Assays for Neurodegenerative Diseases on the Simoa Platform. [PDF]
Böken D +11 more
europepmc +1 more source
Genome-wide identification and expression analysis under selenium stress of glutaredoxin system genes in Cardamine hupingshanensis. [PDF]
Xue H +7 more
europepmc +1 more source
Liraglutide Modulates Zinc Release and Improves Mitochondrial Function in Insulin-Resistant Senescent Cardiomyocytes. [PDF]
Hosseinpourshirazi F +10 more
europepmc +1 more source
Related searches:
Intercomparison on PD calibrators and PD instruments
11th International Symposium on High-Voltage Engineering (ISH 99), 1999Within the framework of a European project, two partial discharge calibrators were circulated to thirteen laboratories for an intercomparison of impulse charge measurements in the range between 1 pC and 500 pC. The deviations of the charge values q reported by the laboratories were, with a very few exceptions, within ±(0,1 pC + 0,03-q).
SCHON K +23 more
openaire +3 more sources
A standard calibrator for PD testing
Conference Record of the 1992 IEEE International Symposium on Electrical Insulation, 2003In the classical partial discharge (PD) measuring circuit the current represents the signal that allows the detection of PDs in the tested sample. This current is converted into a voltage by the measuring impedance, amplified, and filtered. The integration process is essential.
E. Carminati, A. Gandelli, P. Osvath
openaire +1 more source
Development and application of a programmable PD calibrator
2008 Conference on Precision Electromagnetic Measurements Digest, 2008A programmable partial discharge calibrator is described, which is constituted by an arbitrary waveform generator series connected to a capacitor. The step voltage waveform supplied by the generator is software controlled. The characteristics and the capabilities of the calibrator are presented and the procedures adopted for its characterization are ...
M. Chiampi, G. Crotti, Y. Hu, A. Sardi
openaire +1 more source
New approach to calibration in PD measurements
IMTC/99. Proceedings of the 16th IEEE Instrumentation and Measurement Technology Conference (Cat. No.99CH36309), 2003Two different PD measurement instruments could detect different PD values on the same test object even if the measurement conditions are identical. This result is due to the quasi integration error presents in classical PD measurement systems. In this paper the quasi integration error is investigated and two parameters are proposed to qualify the PD ...
E. Carminati, M. Lazzaroni
openaire +1 more source
PD apparent charge estimation and calibration: A critical review
IEEE Transactions on Dielectrics and Electrical Insulation, 2010This paper focuses on the limits of partial discharge apparent charge estimation and calibration using an unified approach. The fundamental problems that prevent accurate apparent charge estimates (resonances, attenuation and partial discharge pulse splitting) are tackled through this approach, highlighting the physical limitations that prevent partial
CAVALLINI, ANDREA +2 more
openaire +1 more source

