Effects of spot parameters in pencil beam scanning treatment planning
Medical Physics, 2017BackgroundSpot size σ (in air at isocenter), interspot spacing d, and spot charge q influence dose delivery efficiency and plan quality in Intensity Modulated Proton Therapy (IMPT) treatment planning. The choice and range of parameters varies among different manufacturers.
Aafke Christine, Kraan +5 more
openaire +2 more sources
Development of Pencil Beam Scanning Nozzle System
2009Purpose: Several types of pencil beam scanning system for proton therapy have been developed and applied to clinical treatment. In case of pencil beam scanning using cyclotron as the proton source, it is common to use continuous scanning method. Then scanning speed and beam current are modulated simultaneously[for full text, please go to the a.m. URL]
Asaba, T +5 more
openaire +2 more sources
Experimentally validated pencil beam scanning source model in TOPAS
Physics in Medicine and Biology, 2014The presence of a low-dose envelope, or 'halo', in the fluence profile of a proton spot can increase the output of a pencil beam scanning field by over 10%. This study evaluated whether the Monte Carlo simulation code, TOPAS 1.0-beta 8, based on Geant4.9.6 with its default physics list, can predict the spot halo at depth in phantom by incorporating a ...
Liyong, Lin +4 more
openaire +2 more sources
Investigation of scan path optimization in improving proton pencil beam scanning continuous delivery
Physics in Medicine & Biology, 2023Abstract Objective . To investigate the impact of scan path optimization on the dose accuracy and beam delivery time (BDT) of proton pencil beam scanning in the dose-driven continuous scanning (DDCS). Approach .
Chunbo Liu +8 more
openaire +2 more sources
Parametric Synthesis of Well-Scanning Isophoric Pencil Beams
IEEE Transactions on Antennas and Propagation, 2017Interest in uniformly illuminated (isophoric) density-tapered planar antenna arrays has recently revived. For arrays consisting of concentric rings of elements, we present a nonstochastic algorithm that calculates ring radii for generation of pencil beams without the need for prior specification of the number of rings.
Salas-Sanchez, AA +3 more
openaire +2 more sources
Contour scanning, multi-leaf collimation and the combination thereof for proton pencil beam scanning
Physics in Medicine & Biology, 2018Abstract In proton therapy, the lateral fall-off is often used to spare critical organs. It is therefore crucial to improve the penumbra for proton pencil beam scanning. However, previous work has shown that collimation may not be necessary for depths of >15 cm in water.
Winterhalter, Carla +5 more
openaire +4 more sources
Multi-purpose nozzle for pencil beam scanning and wobbling
2009PTCOG 48; Meeting of the Particle Therapy Co-Operative ...
Tachikawa, T +5 more
openaire +2 more sources
Technical Note: Spot characteristic stability for proton pencil beam scanning a)
Medical Physics, 2016Purpose:The spot characteristics for proton pencil beam scanning (PBS) were measured and analyzed over a 16 month period, which included one major site configuration update and six cyclotron interventions. The results provide a reference to establish the quality assurance (QA) frequency and tolerance for proton pencil beam scanning.Methods:A simple ...
Chin-Cheng, Chen +4 more
openaire +2 more sources
Clinical Pencil Beam Scanning: Present and Future Practices
2016Pencil beam scanning (PBS) is the most advanced beam delivery technology in particle therapy nowadays. After a pioneering phase, PBS is rapidly becoming available on a larger scale worlwide, and is expected to be the standard beam delivery technique in the future to come.
Marco Schwarz +7 more
openaire +1 more source
Wind measurement resolution for a scanning pencil beam scatterometer
Proceedings of IGARSS '94 - 1994 IEEE International Geoscience and Remote Sensing Symposium, 2005The problem of determining the effective wind measurement resolution of a wind scatterometer is considered. Using simplifying assumptions and approximations, a simple linear model for wind retrieval is derived and related to the effective wind estimate resolution and the backscatter measurement resolution.