Pencil Beam Scanning Carbon Ion Radiotherapy for Hepatocellular Carcinoma [PDF]
Wenna Zhang,1– 3 Xin Cai,1– 3 Jiayao Sun,2– 4 Weiwei Wang,2– 4 Jingfang Zhao,2– 4 Qing Zhang,1– 3 Guoliang Jiang,1– 3,5 Zheng Wang1– 3,5 1Department of Radiation Oncology, Shanghai Proton and Heavy Ion Center, Shanghai, People’s Republic of China ...
Zhang W +7 more
doaj +4 more sources
Implementing ocular treatment with pencil beam scanning: the FHCC experience [PDF]
Background The Fred Hutchinson Cancer Center (FHCC) has developed a novel in-house method for ocular proton therapy by adapting a pencil beam scanning (PBS) beamline and using a commercial treatment planning system.
Jatinder Saini +8 more
doaj +5 more sources
Proton Therapy for Uveal Melanoma on a Pencil Beam Scanning Gantry [PDF]
Purpose: We present our experience treating ocular tumors in a standard pencil beam scanning (PBS) gantry room without apertures, which could broaden access to proton therapy for patients with ocular cancer globally.
Hang Qi, PhD +17 more
doaj +4 more sources
Beam Position Projection Algorithms in Proton Pencil Beam Scanning [PDF]
Beam position uncertainties along the beam trajectory arise from the accelerator, beamline, and scanning magnets (SMs). They can be monitored in real time, e.g., through strip ionization chambers (ICs), and treatments can be paused if needed. Delivery is more reliable and accurate if the beam position is projected from monitored nozzle parameters to ...
Konrad Pawel Nesteruk +2 more
exaly +4 more sources
Absolute dosimetry for FLASH proton pencil beam scanning radiotherapy
A paradigm shift is occurring in clinical oncology exploiting the recent discovery that short pulses of ultra-high dose rate (UHDR) radiation—FLASH radiotherapy—can significantly spare healthy tissues whilst still being at least as effective in curing ...
Ana Lourenço +14 more
doaj +4 more sources
Pencil beam scanning proton lattice radiotherapy: single-field versus multi-field optimization [PDF]
ObjectiveTo evaluate the advantages and disadvantages of single-field versus multi-field optimization in the clinical implementation of pencil beam scanning (PBS) proton lattice radiotherapy (LRT).MethodsLRT proton plans were created retrospectively for ...
Shouyi Wei +23 more
doaj +2 more sources
Applications of various range shifters for proton pencil beam scanning radiotherapy [PDF]
Background A range pull-back device, such as a machine-related range shifter (MRS) or a universal patient-related range shifter (UPRS), is needed in pencil beam scanning technique to treat shallow tumors.
Haibo Lin +11 more
doaj +5 more sources
Patient-Specific Quality Assurance in Pencil Beam Scanning by 2-Dimensional Array [PDF]
Purpose: This study aimed to determine the characteristics of 2D ionization chamber array and the confidence limits of the gamma passing rate in pencil beam scanning proton therapy.
Nuttida Rawiwan, MSc +4 more
doaj +2 more sources
Range-compensated pencil beam scanning proton Arc therapy: a feasibility study [PDF]
Proton arc therapy is a conceptual treatment technique in proton therapy that delivers a scanned proton pencil beam simultaneously as the gantry is rotated around the patient, exploiting the geometric advantages of a continuous arc with the dosimetric ...
Blake R. Smith +3 more
doaj +2 more sources
Fast MCsquare-Based Independent Dose Verification Platform for Pencil Beam Scanning Proton Therapy
Purpose: To commission MCsquare (a multi-cores CPU-based dose calculation engine) for pencil beam scanning (PBS) proton therapy, integrate it into RayStation treatment plan system (TPS) to create a dedicated platform for fast independent dose ...
Chunbo Liu +8 more
doaj +2 more sources