Results 21 to 30 of about 4,358 (152)
Determination of surface dose in pencil beam scanning proton therapy [PDF]
Purpose/objectiveQuantification of surface dose within the first few hundred water equivalent µm is challenging. Nevertheless, it is of large interest for the proton therapy community to study dose effects in the skin. The experimental determination is affected by the detector properties, such as the detector volume and material.
A. Kern +6 more
openaire +2 more sources
Correction: A novel approach for proton therapy pencil beam scanning patient specific quality assurance using an integrated detector system and 3D dose reconstruction [PDF]
Joseph J. Bateman +16 more
doaj +2 more sources
Technical Delivery Parameters of 2000 Proton Treatment Courses [PDF]
Purpose: To summarize the technical delivery parameters of proton plans delivered at the Mayo Clinic in Rochester, Minnesota. Materials and Methods: The database of treated patient proton plans was queried to extract field parameters such as gantry angle,
Amanda J. Deisher +5 more
doaj +1 more source
Dosimetric Comparison of Various Spot Placement Techniques in Proton Pencil Beam Scanning [PDF]
Purpose: To present quantitative dosimetric evaluations of five proton pencil beam spot placement techniques. Materials and Methods: The spot placement techniques that were investigated include two grid-based (rectilinear grid and hexagonal grid, both ...
Mahboob ur Rehman, PhD +5 more
doaj +1 more source
Treatment of ocular tumors on dedicated scattering-based proton therapy systems is standard afforded due to sharp lateral and distal penumbras. However, most newer proton therapy centers provide pencil beam scanning treatments.
Rajesh Regmi +9 more
doaj +1 more source
Parallel‐plates‐based Dirac Leaky Wave Antennas
In this work, the authors experimentally show Dirac Leaky Wave Antennas (DLWAs) at upper microwave frequencies. For the first time, DLWAs are implemented using simple Parallel plate waveguide (PPW) technology, while yielding desirable radiation features ...
Sina Rezaee +2 more
doaj +1 more source
FLASH irradiations use dose-rates orders of magnitude higher than commonly used in patient treatments. Such irradiations have shown interesting normal tissue sparing in cell and animal experiments, and, as such, their potential application to clinical ...
Konrad P. Nesteruk, Serena Psoroulas
doaj +1 more source
Purpose: Quantification of integral radiation dose delivered during treatment for prostate cancer is lacking. We performed a comparative quantification of dose to nontarget body tissues delivered via 4 common radiation techniques: conventional volumetric
Vincent P. Grzywacz, MD +10 more
doaj +1 more source
Layout optimization of the beam spot locations scanned by electromagnets in particle beam therapy
This paper presents a layout optimization method of the spot locations of pencil beam scanning for particle beam cancer therapy. With the pencil beam scanning technique, the particle beam is scanned from spot to spot in the tumor by using scanning ...
Yusuke SAKAMOTO +4 more
doaj +1 more source
Pencil Beam Scanning Proton Therapy for Rhabdomyosarcoma of the Biliary Tract [PDF]
Rhabdomyosarcoma (RMS) is the most common soft tissue sarcoma of childhood with 250-350 cases diagnosed annually in the United States. Biliary tract rhabdomyosarcoma is rare, representing
Pater, Luke +2 more
openaire +2 more sources

