Results 31 to 40 of about 5,745 (213)

Voltammetric Analysis of Cephalexin and Cefazoline in Pharmaceutical Formulation and Biological Samples

open access: yesJournal of the Turkish Chemical Society, Section A: Chemistry, 2019
In this study, the electrochemical behaviors of cephalexin and cefazoline on disposable pencil graphite electrode were investigated in phosphate buffer at pH of 4.5 to 6.0 by differential pulse voltammetry.
Sabriye Perçin Özkorucuklu   +2 more
doaj   +1 more source

Automated pencil electrode formation platform to realize uniform and reproducible graphite electrodes on paper for microfluidic fuel cells

open access: yesScientific Reports, 2020
Graphite pencil stroked electrodes for paper-based Microfluidic devices are gaining immense attention due to their electrochemical properties, cost efficiency, and ease-of-use.
Lanka Tata Rao   +4 more
doaj   +1 more source

Review on carbon-derived, solid-state, micro and nano sensors for electrochemical sensing applications [PDF]

open access: yes, 2009
The aim of this review is to summarize the most relevant contributions in the development of electrochemical sensors based on carbon materials in the recent years.
Davidson, Jimmy L.   +4 more
core   +1 more source

Voltammetric determination of tannic acid in beverages using pencil graphite electrode [PDF]

open access: yesCzech Journal of Food Sciences, 2015
The pretreated pencil graphite electrode (Pre-PGE) prepared by a chronoamperometry technique was applied for the determination of tannic acid using anodic stripping differential pulse voltammetry. The currents obtained from voltammetry measurements at optimum conditions were linearly correlated with the concentration of tannic acid.
DİLGİN, YUSUF   +3 more
openaire   +3 more sources

A Molecularly Imprinted Polymer Based Biosensor for Electrochemical Impedance Spectroscopic Analysis

open access: yesElectrica, 2018
A molecularly imprintedpolymer (MIP)-based impedimetric biosensor was developed for theelectrochemical analysis of low-weight biological molecules. Syntheticpolymeric matrices with specific and selective recognition sites, which arecomplementary to the ...
Feride Şermin Utku   +2 more
doaj   +1 more source

Controlled Electrokinetic Particle Manipulation using Paper-and-Pencil Microfluidics

open access: yes, 2018
Dielectrophoresis is a very promising technique for particle manipulation on a chip. In this study, we demonstrate a controlled mannuvering of polystryrene particles on a simple paper-and-pencil based device by exploiting the underlying electrokinetics ...
Chakraborty, Suman   +4 more
core   +1 more source

Rapid prototyping of carbon-based chemiresistive gas sensors on paper [PDF]

open access: yes, 2013
Chemically functionalized carbon nanotubes (CNTs) are promising materials for sensing of gases and volatile organic compounds. However, the poor solubility of carbon nanotubes hinders their chemical functionalization and the subsequent integration of ...
Azzarelli, Joseph Michael   +4 more
core   +1 more source

Engineered carbon-nanomaterial-based electrochemical sensors for biomolecules [PDF]

open access: yes, 2016
The study of electrochemical behavior of bioactive molecules has become one of the most rapidly developing scientific fields. Biotechnology and biomedical engineering fields have a vested interest in constructing more precise and accurate voltammetric ...
Block W. D.   +8 more
core   +1 more source

Graphite Based Electrode for ECG Monitoring: Evaluation under Freshwater and Saltwater Conditions

open access: yesSensors, 2016
We proposed new electrodes that are applicable for electrocardiogram (ECG) monitoring under freshwater- and saltwater-immersion conditions. Our proposed electrodes are made of graphite pencil lead (GPL), a general-purpose writing pencil.
Tharoeun Thap, Kwon-Ha Yoon, Jinseok Lee
doaj   +1 more source

Pre-Anodized Graphite Pencil Electrode Coated with a Poly(Thionine) Film for Simultaneous Sensing of 3-Nitrophenol and 4-Nitrophenol in Environmental Water Samples

open access: yesSensors, 2022
A very simple, as well as sensitive and selective, sensing protocol was developed on a pre-anodized graphite pencil electrode surface coated using poly(thionine) (APGE/PTH). The poly(thionine) coated graphite pencil was then used for simultaneous sensing
Vijaya Gopalan Sree   +2 more
doaj   +1 more source

Home - About - Disclaimer - Privacy