The Effects of Combining Drill Diameters Bypass, and Implant Bed under Preparation Protocols on Primary Stability of Dental Implant in Low-Density Bones (Experimental Study) [PDF]

open access: yesAl-Rafidain Dental Journal, 2020
Aims: The aim of the current study is to compare the impact of using different drilling protocols on the dental implants primary stability inserted in the low-density bones.
Zaid Faris Y. Bashir   +1 more
doaj   +1 more source

Innovations in Implant Osseointegration: Biomaterials, Surface Engineering, and Translational Strategies

open access: yesJournal of Biomedical Materials Research Part A, Volume 114, Issue 4, April 2026.
ABSTRACT Osseointegration is critical for the long‐term success of orthopedic and dental implants. This review highlights the biological mechanisms underlying bone‐implant integration and recent advances in bioactive materials, drug delivery systems, and surface modification strategies.
Yujin Ahn   +7 more
wiley   +1 more source

The Periotest method.

open access: yesInternational dental journal, 1993
The Periotest is a new instrument for the diagnosis of periodontal diseases. The 'Periotest value' depends to some extent on tooth mobility, but mainly on the damping characteristics of the periodontium. The Periotest measures the reaction to a reproducible impact applied to the tooth crown. The Periotest value is a biophysical parameter.
W, Schulte, D, Lukas
openaire   +1 more source

Wired/Classic and Wireless/Periotest “M” Instruments: An In Vitro Assessment of Repeatability of Stability Measurements

open access: yes, 2014
This in vitro study evaluated agreement among 10 trained evaluators when assessing implant stability with the Wired/Classic and Wireless/Periotest “M.” A difference of 1 Periotest value (PTV) between the wired (−7) and wireless (−8) instruments was ...
Patricia M. Crum   +4 more
core   +1 more source

Objective Assessment of Tooth Mobility Using the Osstell Device: A Pilot Study

open access: yesDiagnostics
Background/Objectives: The objective assessment of natural tooth mobility remains challenging in clinical practice. This pilot study aimed to investigate the feasibility, repeatability, and agreement of a modified implant stability measurement system ...
Kübra Erdoğan Eryıldız   +3 more
doaj   +1 more source

Torque Accuracy of Spring‐Style Dental Torque Wrenches After Repeated Mechanical Loading and Sterilization: An In Vitro Study

open access: yesInternational Journal of Dentistry, Volume 2026, Issue 1, 2026.
This in vitro study evaluated the torque accuracy of spring‐style mechanical torque‐limiting devices (MTLDs) from three manufacturers under clinically simulated conditions. Nine devices (Implance, Astra Tech, and DIO) were tested with a digital torque tester. Target torque values were 25 and 35 Ncm for Implance and Astra Tech and 20 and 35 Ncm for DIO.
Batuhan Aydın   +3 more
wiley   +1 more source

Assessment of a Power Chain as a New Dental Trauma Splint and Its Comparison with Two Commonly Used Splinting Materials

open access: yesApplied Sciences, 2020
Background: Stabilization of luxated, avulsed, and root-fractured teeth is a part of the dental trauma treatment. The aim of the study was to assess the power chain and its comparison with two commonly used splinting materials.
Hanna Sobczak-Zagalska   +1 more
doaj   +1 more source

Impact of retraction force magnitudes on mobility of maxillary canines: a split-mouth design

open access: yesProgress in Orthodontics, 2022
Objective Prospective evaluation of the maxillary canine mobility during retraction using two different force levels over 5 months of retraction. Materials and methods Thirty patients indicated for maximum retraction of maxillary canines with age range ...
Nehal F. Albelasy, Yasser L. Abdelnaby
doaj   +1 more source

Comparative Study of Peri‐Implant Tissues Following Flapless Placement of a One‐Piece Tissue‐Level Implant Versus Open‐Flap Placement of a Two‐Piece Bone‐Level Implant in a Canine Model

open access: yesInternational Journal of Dentistry, Volume 2026, Issue 1, 2026.
Purpose The purpose of this study is to test the hypothesis that the placement of a minimally invasive implant (MII, one‐piece tissue‐level implant) using a flapless/subcrestal protocol provides a better quality of peri‐implant tissues compared to a reference implant (RI, two‐piece bone‐level implant) placed with an open‐flap/crestal protocol in a ...
Aurore Barraco   +5 more
wiley   +1 more source

Valoración de la movilidad dentaria fisiológica en el perro mediante la técnica Periotest [PDF]

open access: yes, 2004
Tesis de la Universidad Complutense de Madrid, Facultad de Veterinaria, Departamento de Medicina y Cirugía Animal, leída el 14-07-2004Se estudiaron 102 animales adultos de la especie canina, hembras y machos, de edades comprendidas entre 1.5-8 años ...
Pérez Lloret, Pilar