Results 51 to 60 of about 612 (165)

Long-term results of immediate implantation in mandibular posterior teeth with early loading: A retrospective case series

open access: yesDental Research Journal, 2022
When immediate molar implants first were proposed, submerged initial healing and delayed loading were the norm. It is now recognized that some early loading of a nonocclusal nature can stimulate faster osseointegration, although full occlusal loading is ...
Nader Ayubianmarkazi   +4 more
doaj   +1 more source

Evaluation of thin‐threaded implants primary stability in type IV bone right after maxillary sinus floor elevation: A human cadaver study

open access: yesJournal of Prosthodontics, Volume 34, Issue 6, Page 593-601, July 2025.
Abstract Purpose The bone‐implant interface plays a crucial role in obtaining sufficient primary stability for dental implants in weak bone supports. The aim of this human cadaver study was to evaluate the primary stability of new thin‐threaded implants when placed in type IV bone right after maxillary sinus floor elevation.
Jean‐Christophe Coutant   +5 more
wiley   +1 more source

Local delivery of pamidronate with collagen matrix mitigates buccal bone resorption following immediate implant placement – An experimental in vivo study

open access: yesJournal of Periodontal Research, Volume 60, Issue 3, Page 255-264, March 2025.
Local delivery of pamidronate with collagen matrix mitigates buccal bone resorption following immediate implant placement. The group with pamidronate soaked collagen membrane showed significantly reduced buccal bone resorption. Abstract Aims The aim of this experimental in vivo pilot study was to evaluate the effect of the local delivery of pamidronate
Inpyo Hong   +6 more
wiley   +1 more source

Comparative Efficiency of Removable Mini-Implant Retained Dentures Using Different Attachments in Edentulous Patients

open access: yesКубанский научный медицинский вестник, 2019
Aim. To compare the efficiency of removable mini-implant retained dentures using different types of attachment.Materials and methods. The study included 51 edentulous patients.
Stanislav Yu. Maksyukov   +6 more
doaj   +1 more source

The Evaluation of the Reliability of Periotest for Implant Stability Measurements: An In Vitro Study

open access: yesJournal of Oral Implantology, 2015
Periotest (Medizintechnik Gulden, Modautal, Germany) is a widely accepted implant stability measurement method, although the reliability is not well known. The aim of this in vitro study was to investigate the reliability of the Periotest in implant stability measurements. Thirty implants were placed in 3 cow ribs.
Bilhan, Hakan   +5 more
openaire   +2 more sources

Osseodensification technique in crestal maxillary sinus elevation—A narrative review

open access: yesClinical Implant Dentistry and Related Research, Volume 27, Issue 1, February 2025.
Abstract Osseodensification is a novel approach that has significantly advanced the field of implant dentistry, particularly in the context of transcrestal maxillary sinus floor elevation. This technique involves the use of specially designed burs that compact and densify bone along the osteotomy walls, thereby enhancing implant primary stability and ...
João Gaspar   +2 more
wiley   +1 more source

Implant Osseointegration Adjacent to a Retained Root Fragment: A Case With 11‐Year Follow‐up

open access: yesCase Reports in Dentistry, Volume 2025, Issue 1, 2025.
Introduction: There is a growing demand for implant dentistry as the first choice of rehabilitation for treating patients with missing teeth. Clinicians can encounter asymptomatic retained root fragments in edentulous spaces. This case report presents the long‐term prognosis of an implant resulting in late failure, with an attached root remnant to the ...
Esra Uyguc   +4 more
wiley   +1 more source

Diagnosis in Periodontology and Implant Dentistry: The Past, the Present, the Future

open access: yes
Journal of Periodontal Research, Volume 61, Issue 3, Page 225-232, March 2026.
Lisa J. A. Heitz‐Mayfield
wiley   +1 more source

Nondestructive acoustic modal analysis for assessing bone screw stability: An ex vivo animal study

open access: yesJournal of Orthopaedic Research, Volume 42, Issue 12, Page 2743-2751, December 2024.
Abstract Conventional insertion torque and pull‐out tests are destructive and unsuitable for clinical bone screw fixation. This study evaluates screw stability using acoustic modal analysis (AMA) and Periotest compared to traditional methods in an ex vivo animal model. Titanium self‐tapping screws (STS) and nonself‐tapping screws (N‐STS) were implanted
Mohammadjavad (Matin) Einafshar   +5 more
wiley   +1 more source

Correlation Between Implant Stability Quotient and Percussion Sound Frequency

open access: yesClinical and Experimental Dental Research, Volume 10, Issue 4, August 2024.
ABSTRACT Objectives To determine the correlation between the primary implant stability quotient and the implant percussion sound frequency. Materials and Methods A total of 14 pigs' ribs were scanned using a dental cone beam computed tomography (CBCT) scanner to classify the bone specimens into three distinct bone density Hounsfield units (HU) value ...
Wansiri Peeraprasompong   +2 more
wiley   +1 more source

Home - About - Disclaimer - Privacy