Realistic phantoms for quantitative MR: the need and a proposal (the B1 sleeve)
Quantitative MR (qMR) has offered direct access to in-vivo biology and physiology for over three decades, yet it has failed to translate into the clinic. Why is this? The development of suitable phantoms is a key stage in the evolution of qMR, and here a
Paul S Tofts
doaj
ABSTRACT Background In radiotherapy for early‐stage glottic cancer, evaluating the target surface dose at the glottic air–tissue boundary is crucial, as buildup effect can cause underdosing. The accuracy of dose evaluation in the surrounding tissues is affected by both the dose calculation algorithms and the accuracy of the Hounsfield unit values in ...
Yuki Saito+3 more
wiley +1 more source
Abstract Purpose Training deep learning dose prediction models for the latest cutting‐edge radiotherapy techniques, such as AI‐based nodal radiotherapy (AINRT) and Daily Adaptive AI‐based nodal radiotherapy (DA‐AINRT), is challenging due to limited data.
Hui‐Ju Wang+5 more
wiley +1 more source
Abstract Purpose To compare plan quality among photon volumetric modulated arc therapy (VMAT) and intensity‐modulated proton therapy (IMPT) with robustness using three different proton beam delivery systems with various spot size (σ) ranges: cyclotron‐generated proton beams (CPBs) (σ: 2.7–7.0 mm), linear accelerator proton beams (LPBs) (σ: 2.9–5.5 mm),
Tara Gray+9 more
wiley +1 more source
IROC phantoms accurately detect MLC delivery errors
Abstract Purpose We evaluated the impact of random and whole‐bank multileaf collimator (MLC) delivery errors on dosimetric delivery accuracy in the Imaging and Radiation Oncology Core (IROC) phantom audits, as well as differences in delivery accuracy between the IROC phantom prescription and typical clinical fraction sizes.
Sharbacha S. Edward+5 more
wiley +1 more source
The effect of multi‐leaf collimator leaf width on VMAT treatment plan quality
Abstract Background The advent of volumetric modulated arc therapy (VMAT) in radiotherapy has made it one of the most commonly used techniques in clinical practice. VMAT is the delivery of intensity modulated radiation therapy (IMRT) while the gantry is in motion, and existing literature has shown it has decreased treatment delivery times and the ...
Gregory Sadharanu Peiris+3 more
wiley +1 more source
Abstract Purpose Quantify the impact of additional imaging doses on clinical dose constraints during lung stereotactic body radiotherapy (SBRT) treatment utilizing stereoscopic/monoscopic real‐time tumor monitoring. Materials and Methods Thirty lung SBRT patients treated with the volumetric arc therapy technique were randomly selected from the ...
Ruwan Abeywardhana, Mike Sattarivand
wiley +1 more source
JACMP – Founding and 2000–2004
Journal of Applied Clinical Medical Physics, EarlyView.
Michael Mills
wiley +1 more source
Abstract Purpose Cardiac motion may degrade dose distribution during stereotactic arrhythmia radioablation using the CyberKnife system, a robotic radiosurgery system. This study evaluated the dose distribution changes using a self‐made cardiac dynamic platform that mimics cardiac motion. Methods The cardiac dynamic platform was operated with amplitudes
Takayuki Miyachi+6 more
wiley +1 more source