Results 11 to 20 of about 1,320 (265)

Phasor Measurement Unit Test Under Interference Conditions [PDF]

open access: yesIEEE Transactions on Power Delivery, 2018
This paper investigates the performance of phasor measurement units (PMUs) under interference conditions, which can appear in a power system and are not tested by the C37.118.1 standard. Three PMUs from different vendors configured for the M-class requirements were used to test three possible interference condition scenarios.
Radu Ghiga   +3 more
openaire   +2 more sources

A Fully Informative Phasor Measurement Unit for Distribution Networks With Harmonic Distortion

open access: yesIEEE Access, 2022
We introduce a fully informative distribution network phasor measurement unit (FI-DPMU), that is capable of performing a simultaneous estimation of phasor dynamics and harmonic components.
David S. Pacheco-Cherrez   +4 more
doaj   +1 more source

Instantaneous Frequency Estimation Algorithm for Power Systems [PDF]

open access: yesJES: Journal of Engineering Sciences, 2022
This paper deals with the problem of the Instantaneous Frequency (IF) estimation of power systems, to be adopted for example in Phasor Measurement Units (PMUs) used for monitoring, control, and protection.
Christina Aziz   +2 more
doaj   +1 more source

False Data Injection Detection for Phasor Measurement Units

open access: yesSensors, 2022
Cyber-threats are becoming a big concern due to the potential severe consequences of such threats is false data injection (FDI) attacks where the measures data is manipulated such that the detection is unfeasible using traditional approaches. This work focuses on detecting FDIs for phasor measurement units where compromising one unit is sufficient for ...
Saleh Almasabi   +6 more
openaire   +5 more sources

Filters for M class Phasor Measurement Units [PDF]

open access: yes2012 IEEE International Workshop on Applied Measurements for Power Systems (AMPS) Proceedings, 2012
The new standard C37.118.1 lays down strict performance limits for phasor measurement units (PMUs) under steady-state and dynamic conditions. Reference algorithms are also presented for the P (performance) and M (measurement) class PMUs. In this paper, the performance of the Reference M class filter is analysed.
Roscoe, Andrew   +2 more
openaire   +2 more sources

Distributed Generation installed by the Phasor Measurement Unit to improve voltage

open access: yesJurnal Ilmiah SINERGI, 2022
This study is intended to design a system connected to the Distributed Generation (DG) sourced from solar cells, using Matlab/Simulink. A Phasor Measurement Unit (PMU) is installed in the DG system to monitor the phasor voltage and current.
Azriyenni Azhari Zakri   +3 more
doaj   +1 more source

Penempatan Phasor Measurement Unit untuk Menentukan Prediksi Margin Kestabilan Tegangan

open access: yesJurnal Nasional Teknik Elektro dan Teknologi Informasi, 2019
The development of power system in new transmission and generation facilities has burdened the power system more than before. As a consequence, many power systems are facing voltage problems which will lead to voltage instability.
Levin Halim   +2 more
doaj   +1 more source

Phasor data concentrator placement in phasor measurement unit networks considering communication channel uncertainty and failure

open access: yesIET Smart Grid, 2023
One challenge in Wide Area Measurement System is to design a reliable network which assures data availability. The availability of data in Phasor Measurement Unit (PMU) networks depends on two factors: 1‐Reliable data measurements which depend on ...
Maryam Dehghani, Navid Vafamand
doaj   +1 more source

Phasor Measurement Unit Incorporated Adaptive Out-of-step Protection of Synchronous Generator

open access: yesJournal of Modern Power Systems and Clean Energy, 2021
The existing out-of-step (OOS) protection schemes have proven to be deficient in the prevention of significant outages. OOS protection schemes must not operate in stable power swing, and rapidly isolate an asynchronous generator or group of generators ...
Jigneshkumar P. Desai, Vijay H. Makwana
doaj   +1 more source

Development of a reference Phasor Measurement Unit (PMU) for the monitoring and control of grid stability and quality

open access: yesEPJ Web of Conferences, 2014
This paper discusses the details of the development of a Phasor Measurement Unit regarding the requirements of the IEEE C37.118-2005 synchrophasor standard relative to steady-state conditions on grid monitoring and control.
Ndilimabaka Hervé, Blanc Isabelle
doaj   +1 more source