Results 101 to 110 of about 4,943,789 (197)

Optimal phasor measurement unit (PMU) placement for the power systems with existing SCADA measurements

open access: yes, 2020
It is extremely important to maintain efficiency, sustainability and reliability of the generation, transmission and distribution of the electrical energy; hence it is mandatory to monitor the system in real time. State estimation has a key role in real time monitoring of a power system.
openaire   +1 more source

Smart5Grid Solutions for enhanced TSO grid observability and manageability in massive RES penetration environment. [PDF]

open access: yesOpen Res Eur, 2023
Shangov D   +11 more
europepmc   +1 more source

Risk control method for power data support based on embedded technology

open access: yesDianxin kexue
In order to improve the ability of bad data identification and fault location accuracy in power system risk control, a new risk control method for power systems using embedded technology was designed.S3C2440 chip was used as the central processing unit ...
Chengyue YANG   +3 more
doaj   +2 more sources

PMU Placement Methods in Power Systems based on Evolutionary Algorithms and GPS Receiver

open access: yesIranian Journal of Electrical and Electronic Engineering, 2013
In this paper, optimal placement of Phasor Measurement Unit (PMU) using Global Positioning System (GPS) is discussed. Ant Colony Optimization (ACO), Simulated Annealing (SA), Particle Swarm Optimization (PSO) and Genetic Algorithm (GA) are used for this ...
M. R. Mosavi, A. Akhyani
doaj  

Design and implementation of a phasor measurement unit using a new measurement technique. [PDF]

open access: yesSci Rep
Mohamed SA   +5 more
europepmc   +1 more source

MV grid discovery via Phasor Measurements Units (PMUs)

open access: yes
Este proyecto de tesis estudia la localización de fallas basada en PMU en redes de distribución de media tensión, con un enfoque en soluciones que una empresa de servicios públicos podría implementar realmente. El núcleo del trabajo busca determinar si un estimador de impedancia de un solo extremo, apoyado por un pequeño conjunto de PMUs ...
openaire   +1 more source

Modeling of SCADA and PMU Measurement Chains [PDF]

open access: yes
In this document, the supervisory control and data acquisition (SCADA) and phasor measurement unit (PMU) measurement chain modeling will be studied, where the measurement error sources of each component in the SCADA and PMU measurement chains and the ...
Lin, Yuzhang, Cheng, Gang
core  