Phasor Measurement Unit Test Under Interference Conditions [PDF]
This paper investigates the performance of phasor measurement units (PMUs) under interference conditions, which can appear in a power system and are not tested by the C37.118.1 standard. Three PMUs from different vendors configured for the M-class requirements were used to test three possible interference condition scenarios.
Radu Ghiga +3 more
openaire +2 more sources
Advanced Distribution Measurement Technologies and Data Applications for Smart Grids: A Review
The integration of advanced measuring technologies in distribution systems allows distribution system operators to have better observability of dynamic and transient events. In this work, the applications of distribution grid measurement technologies are
Antonio E. Saldaña-González +3 more
doaj +1 more source
Data-Driven Method for Missing Harmonic Data Completion
In large-scale applications, missing harmonic data during transmission is inevitable. This paper presents a novel approach for the completion of missing harmonic data based on a data-driven approach.
Rui Xu +4 more
doaj +1 more source
Phasor Estimation for Grid Power Monitoring: Least Square vs. Linear Kalman Filter [PDF]
International ...
Ahmed, Hafiz +4 more
core +3 more sources
Filters for M class Phasor Measurement Units [PDF]
The new standard C37.118.1 lays down strict performance limits for phasor measurement units (PMUs) under steady-state and dynamic conditions. Reference algorithms are also presented for the P (performance) and M (measurement) class PMUs. In this paper, the performance of the Reference M class filter is analysed.
Roscoe, Andrew +2 more
openaire +2 more sources
The Paradigm Revolution in the Distribution Grid: The Cutting-Edge and Enabling Technologies
Bi-directional information and energy flow, renewable energy sources, battery energy storage, electric vehicle, self-healing capability, and demand response programs, etc., revolutionized the traditional distribution network into the smart distribution ...
Thasnimol C M, Rajathy R.
doaj +1 more source
Closed-Form Expressions to Estimate the Mean and Variance of the Total Vector Error
The need for accurate measurements and for estimating the uncertainties associated with measures are two pillars for researchers and metrologists. This is particularly true in distribution networks due to a mass deployment of new intelligent electronic ...
Alessandro Mingotti +3 more
doaj +1 more source
Monitoring of power system dynamics under incomplete PMU observability condition
This work presents a hybrid state estimation procedure that allows power system dynamics associated to slow and fast transient events to be accurately monitored considering a limited amount of phasor measurement units. The proposal represents an enhanced
Gabriel Ortiz +2 more
doaj +1 more source
Improved BPSO for optimal PMU placement [PDF]
Optimal phasor measurement unit (PMU) placement involves the process of minimizing the number of PMU needed while ensuring entire power system network completely observable.
Rahman, NHA, Theodoridis, M, Zobaa, AF
core +1 more source
Phasor Measurement Units Allocation Against Load Redistribution Attacks Based on Greedy Algorithm [PDF]
Power grid vulnerability to various cyber-attacks will undoubtedly increase with the widespread use of cutting-edge computer technologies in power systems monitoring and control.
Ali Rahdan, Ali Khaleghi
doaj +1 more source