Results 31 to 40 of about 4,111,054 (290)

Soft Phasor Measurement Unit

open access: yesProcedia Technology, 2015
AbstractSmart grid is a modernized electrical supply network in which information is communicated bi directionally using digital communication technology. Monitoring, analyzing, controlling and communication occurs within the supply chain thus improving efficiency, reducing energy consumption etc.
Anisha N.P.,   +2 more
openaire   +1 more source

Optimal µPMU Placement Considering Node Importance and Multiple Deployed Monitoring Devices in Distribution Networks

open access: yesEnergies
The placement of micro phasor measurement units in an active distribution network can improve the monitoring performance of the system. However, the price and placement cost of micro phasor measurement units are high, so existing research mostly focuses ...
Ruifeng Zhao   +9 more
doaj   +1 more source

Optimal PMUs Placement Due to Several Stages for Achieving Full System Observability

open access: yesRenewable Energy and Sustainable Development, 2017
The new measurement devices such as phasor measurement units (PMUs), is considered to be an essential component in implementing future power network systems.
Mohamed Badr   +2 more
doaj   +1 more source

A New Phasor Estimator for PMU Applications: P Class and M Class

open access: yesJournal of Modern Power Systems and Clean Energy, 2020
Phasor measurement units (PMUs) are fundamental tools in the applications of modern power systems, where synchronized phasor estimations are needed. The accuracy and dynamic performance requirements for phasor, frequency, and rate of change of frequency (
Jose R. Razo-Hernandez   +4 more
doaj   +1 more source

An advanced wide-area fault detection and location technique for transmission lines considering optimal phasor measurement units allocation

open access: yesAlexandria Engineering Journal, 2022
The transmission system plays a vital role in the electric power system as it links load centers with power generation and, so, it is mandatory to protect this system from any abnormal conditions.
Hossam A. Abd el-Ghany   +2 more
doaj   +1 more source

Dynamic phasor and frequency estimator for phasor measurement units

open access: yesIET Generation, Transmission & Distribution, 2010
Synchrophasors and frequency estimations play an increasingly important role in power systems. Discrete Fourier transform (DFT) may introduce errors into phasor and frequency estimations under dynamic conditions, such as power oscillation. A dynamic phasor and frequency estimator for phasor measurement units (PMUs) is proposed to improve accuracy by ...
R.K. Mai, Z.Y. He, L. Fu, W. He, Z.Q. Bo
openaire   +1 more source

A Multi-objective PMU Placement Method Considering Observability and Measurement Redundancy using ABC Algorithm

open access: yesAdvances in Electrical and Computer Engineering, 2014
This paper presents a Multi- objective Optimal Placement of Phasor Measurement Units (MOPP) method in large electric transmission systems. It is proposed for minimizing the number of Phasor Measurement Units (PMUs) for complete system observability and
KULANTHAISAMY, A.   +3 more
doaj   +1 more source

A Robust Scheme for Coherency Detection in Power Systems

open access: yesJurnal Nasional Teknik Elektro, 2021
This paper presents an approach for online generator coherency identification based on windowed dynamic time warping (DTW). Generator rotor speed deviations measured by phasor measurement units (PMUs) are used as input data to compute a DTW ...
Gideon Adom-Bamfi   +1 more
doaj   +1 more source

Measurement accuracy verification of phasor measurement unit with dynamic phasor estimation

open access: yesArchives of Electrical Engineering, 2018
Power systems that are highly loaded, especially by a stochastic supply of renewables and the presence of storages, require dynamic measurements for their optimal control. Phasor measurement units (PMUs) can be used to capture electrical parameters of a power system.
Bartłomiej Arendarski   +3 more
openaire   +2 more sources

Experience in implementing the algorithm for emergency control system of unloading in case of overload in terms of power based on synchrophasor angle [PDF]

open access: yesE3S Web of Conferences
An algorithm for automatic unloading during a power overload is described. It is based on measurement of the phase angle between voltages on the Tyumen - Ural power transmission line, which is determined by information from phasor measurement units.
Govorun Mikhail   +5 more
doaj   +1 more source

Home - About - Disclaimer - Privacy