Results 271 to 280 of about 146,185 (357)

Immunogenicity of subunit vaccine of E2 protein against atypical porcine pestivirus in pigs. [PDF]

open access: yesFront Cell Infect Microbiol
Huang Y   +5 more
europepmc   +1 more source

Bona Fide Intersegmental Plane Hepatectomy Along the Glissonean Branches (BIPHG)

open access: yesAnnals of Gastroenterological Surgery, EarlyView.
ABSTRACT This review traces the author's personal journey over three decades in the evolution of liver resection techniques, culminating in the proposal of the Bona Fide Intersegmental Plane Hepatectomy Along Glissonean Branches (BIPHG). Beginning with pioneering experiences in laparoscopic and robotic liver surgeries, the author highlights key ...
Go Wakabayashi, Taiga Wakabayashi
wiley   +1 more source

Design, Control, and Clinical Applications of Magnetic Actuation Systems: Challenges and Opportunities

open access: yesAdvanced Intelligent Systems, Volume 7, Issue 3, March 2025.
This review aims to provide a broad understanding for interdisciplinary researchers in engineering and clinical applications. It addresses the development and control of magnetic actuation systems (MASs) in clinical surgeries and their revolutionary effects in multiple clinical applications.
Yingxin Huo   +3 more
wiley   +1 more source

A Soft‐Tip Hydraulically Steerable Catheter for Enhanced Flexibility and Safety in Vascular Interventions

open access: yesAdvanced Intelligent Systems, EarlyView.
This study introduces a hydraulically steerable catheter with a soft tip in vascular procedures. The steering soft tip achieves a minimal diameter of 2.6 mm and supports a 180° bend. Real‐time shape and position tracking, facilitated by segmentation and endpoint detection techniques, improves navigation.
Jingyi Kang   +9 more
wiley   +1 more source

Wirelessly Powered Soft Magnetic Robot with Microneedle for Electrical Stimulation and Drug Delivery

open access: yesAdvanced Intelligent Systems, EarlyView.
A wirelessly powered soft magnetic robot integrates microneedles to enable dual functions: electrical stimulation (86.7% efficiency at 6 cm, tunable 0–20 V voltage, 0.4–50 ms pulses) and drug delivery. It switches surfaces via magnetic fields for gastrointestinal tract locomotion and treatment, with in vitro validation in fresh pig gut showing ...
Song Zhao   +8 more
wiley   +1 more source

Microendovascular Neural Recording from Cortical and Deep Vessels with High Precision and Minimal Invasiveness

open access: yesAdvanced Intelligent Systems, EarlyView.
Intravascular electroencephalography (ivEEG) using micro‐intravascular electrodes was developed. Cortical‐vein ivEEG showed a higher signal‐to‐noise ratio and finer spatial resolution of somatosensory evoked potentials (SEPs) than superior sagittal sinus ivEEG, and deep‐vein ivEEG captured clear visual evoked potentials.
Takamitsu Iwata   +15 more
wiley   +1 more source

Home - About - Disclaimer - Privacy