Results 211 to 220 of about 40,433 (286)

Frozen Differential Scattering in Reconfigurable Complex Media

open access: yesLaser &Photonics Reviews, EarlyView.
A localized perturbation universally results in a rank‐one update of the scattering matrix of any complex medium. The resulting differential output wavefront is “frozen”: its spatial pattern is fixed (agnostic to the input wavefront). Experiments with a programmable‐metasurface‐parametrized wireless link validate frozen differential scattering and ...
Philipp del Hougne
wiley   +1 more source

Time‐Division Multiplexing for Parallel Transmission at Ultra‐High Field With Limited RF Channels

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose Investigating time‐division multiplexing for parallel transmission in ultra high‐field imaging, striving for homogeneous whole brain excitation with a limited number of RF channels. Methods A fast RF switch was built to alternately route 8 transmit channels to each row of a double‐row 16‐element transmit coil array at a 9.4 T human MRI
Felix Glang   +4 more
wiley   +1 more source

A Novel 9‐Channel 1H, 3‐Channel 31P Radiofrequency Coil for Interleaved Multinuclear Studies of Human Calf Muscle at 7 T

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To develop a double‐tuned calf coil with excellent 1H and 31P performance to study muscle physiology by interleaved 1H/31P MRS and parallel imaging at 7 T. Methods The coil combines three 1H transceive dipoles, six 1H receive‐only loops and three 31P transceive loops, arranged in a nested, half‐cylindrical layout.
Veronika Cap   +8 more
wiley   +1 more source

Deuterium 1‐Channel Transmit/16‐Channel High Impedance Receive Array Combined With 16‐Channel 1H Dual‐Row Transceiver Array for 7 Tesla Brain Imaging

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To develop and evaluate an 2H/1H coil configuration that enables deuterium metabolic imaging at 7 T while preserving high‐quality 1H anatomical imaging. Methods An 16‐channel 2H high‐impedance receive array was combined with a 2H transmit birdcage and a 16‐channel dual‐row 1H transceiver array.
Bei Zhang   +3 more
wiley   +1 more source

Assessment of Sensitivity and Specificity of Common Sensory Tests in Diagnosing Digital Nerve Lacerations

open access: yesMuscle &Nerve, EarlyView.
ABSTRACT Introduction/Aims Digital nerve lacerations are common. Current methods employed to differentiate intact and transected digital nerves lack diagnostic accuracy. This may result in patients with intact nerves undergoing unnecessary surgery. The objective of the study was to determine the best diagnostic method for detecting true sensory nerve ...
Joshua N. Wong   +5 more
wiley   +1 more source

Home - About - Disclaimer - Privacy