Results 111 to 120 of about 39,796 (305)

Autonomous Machine Learning‐Based Classification and Arrangement of Submillimeter Objects Using a Capillary Force Gripper

open access: yesAdvanced Intelligent Discovery, EarlyView.
This study presents an automated system integrating a capillary force gripper and machine learning‐based object detection for sorting and placing submillimeter objects. The system achieved stable and simultaneous manipulation of four object types, with an average task time of 86.0 seconds and a positioning error of 157 ± 84 µm, highlighting its ...
Satoshi Ando   +4 more
wiley   +1 more source

Valve actuator Patent [PDF]

open access: yes, 1963
Actuator using compressed gas as driving force to control valve handling large liquid ...
Bacchi, R.
core   +1 more source

FastCat: Autonomous Discovery of Multielement Layered Double Hydroxide Alloy Catalysts for Alkaline Oxygen Evolution Reaction

open access: yesAdvanced Intelligent Discovery, EarlyView.
A machine learning‐guided self‐driving laboratory screened over 500 nickel‐based layered double‐hydroxide catalysts for alkaline oxygen evolution. Out of the eight metals, the robot uncovered a quaternary Ni–Fe–Cr–Co catalysts requiring only 231 mV overpotential to reach 20 mA cm−2.
Nis Fisker‐Bødker   +3 more
wiley   +1 more source

Comprehensive improvement of the surface quality of the diesel engine piston

open access: yesMetalurgija, 2019
An important requirement for the material for pistons concerns its parameters at different temperatures of piston operation at different ambient temperatures.
A. Pacana, K. Czerwińska, L. Bednarova
doaj  

Thickness measuring and injection device Patent [PDF]

open access: yes, 1971
Foam insulation thickness measuring and injection device for spacecraft ...
Spencer, R. L.
core   +1 more source

Patient‐Mounted Neuro Optical Coherence Tomography for Targeted Minimally Invasive Micro‐Resolution Volumetric Imaging in Brain In Vivo

open access: yesAdvanced Intelligent Systems, Volume 7, Issue 3, March 2025.
Herein, a patient‐mounted neuro optical coherence tomography system that integrates a 5 degrees‐of‐freedom skull‐mounted robot (Skullbot) with a 0.6 mm neuroendoscope for targeted, minimally invasive deep brain imaging, is developed. The system offers high‐resolution imaging with precise deployment, demonstrated through successful tumor imaging in a ...
Chao Xu   +7 more
wiley   +1 more source

A Soft Robotic Jellyfish with Decoupled Actuators for Agile 3D Locomotion

open access: yesAdvanced Intelligent Systems, EarlyView.
This study presents a soft robotic jellyfish featuring a functionally decoupled actuation architecture. By separating propulsion, steering, and vertical regulation into independent modules, the robot overcomes conventional coupled‐motion limitations. Utilizing a passive‐valve‐based differential drag strategy and lateral water jets, it achieves agile 3D
Zhuoheng Li   +6 more
wiley   +1 more source

Design‐for‐Benchmarking in Soft Robotics: Navigating Component‐System Dichotomy

open access: yesAdvanced Intelligent Systems, EarlyView.
Soft robotics faces a profound evaluation challenge: the Component‐System Dichotomy, where isolated component tests fail to predict integrated performance. This article presents a systematic survey of critical reporting gaps across actuation, sensing, and control.
Matteo Lo Preti   +4 more
wiley   +1 more source

Refurbishment of the cryogenic coolers for the Skylab earth resources experiment package [PDF]

open access: yes, 1975
Skylab Earth Resources Experiment Package (EREP) experiments, S191 and S192, required a cold temperature reference for operation of a spectrometer. This cold temperature reference was provided by a subminiature Stirling cycle cooler. However, the failure
Luksa, N. C., Smithson, J. C.
core   +1 more source

Isovolumic relaxation strain imaging is an accurate and sensitive approach for detection of active diastolic dysfunction: A preclinical study

open access: yesAnimal Models and Experimental Medicine, EarlyView.
A modified approach was developed to accurately identify the isovolumetric relaxation time (IVRT) using an apical three‐chamber view. Compared with conventional echocardiography, isovolumic relaxation strain imaging (IVSI) helps to detect the earlier alternations of diastolic function in transverse aortic constriction (TAC) mice.
Jingjing Liang   +3 more
wiley   +1 more source

Home - About - Disclaimer - Privacy