Results 21 to 30 of about 106 (70)
Parametric Study of Seismic Performance of Steel Bridges Pier Rehabilitated with Composite Connection [PDF]
Connections pipe pile to cap beam in steel bridges have important roles on structure strength affecting lateral loads such as earthquake. One of the most important strategies are to translate plastic hinge from connections to the other places in ...
Rohola Rahnavard +3 more
doaj +1 more source
Numerical model for investigating seismic performance of Prestressed Hollow Concrete (PHC) piles with Fiber section element [PDF]
In the medium to high seismic zone, prestressed hollow concrete (PHC) pile for structural foundation should be designed with elastic behavior due to low ductility and dissipated energy.
Setiawan Angga Fajar +4 more
doaj +1 more source
The use of precast concrete structures with grouted sleeve (GS) connections has gained significant traction in the acceleration of bridge construction.
Rizky Tri Amalia, Harun Alrasyid
doaj +1 more source
Study Of structural Behaviour And Residual Drift Of Concrete frames Reinforced With Shape Memory Alloy Rebar [PDF]
Buildings in high seismic regions are prone to severe damage and collapse during earthquakes due to large lateral deformations. The use of superelastic shape memory alloys (SMAs) as reinforcements in concrete structures is gradually gaining interest ...
Masoud Mirtaheri +3 more
doaj +1 more source
Bearing Capacity and Deformation of Micropiles Considering Plastic Hinge
This study systematically investigates the plastic deformation behavior and load-bearing mechanisms of micropiles through integrated scaled physical modeling and nonlinear finite element analysis, with particular emphasis on quantifying plastic hinge ...
Yipaliya Abuduweili +3 more
doaj +1 more source
Seismic Performance Evaluation of Wharf Based on ASCE 61-14
The adequacy of the structural performance of a wharf in withstanding seismic loads is of paramount importance. Therefore, this research aims to conduct an accurate pushover analysis on the adequacy of a wharf located in North Sulawesi, Indonesia.
Kukuh Adhi Kafie +3 more
doaj +1 more source
Plastic hinge length is an important parameter when the elastic-plastic analysis is carried out on a structure and it has an important influence on the analysis result.
Bo FENG +3 more
doaj
Using 3D Digital Image Correlation (3D-DIC) to Measure CTOD in a Semi-Elliptical Surface Crack
The subsurface nature of Crack Tip Opening Displacement (CTOD) makes its direct measurement very difficult, if not impossible. During fracture toughness testing, CTOD is commonly calculated by applying a plastic hinge model using externally applied clip ...
Kaveh Samadian +2 more
doaj +1 more source
This study investigates the seismic behavior of the T-shaped concrete-filled steel tubular (CFST) column to steel beam joints, aimed at expanding their applicability in areas with high-seismic fortification intensity. A construction form of T-shaped CFST
Jinyan Wang +5 more
doaj +1 more source
Nonlinear Cyclic Analysis of Reinforced Concrete Columns Using Fiber Section Approach
This study investigates nonlinear modeling and verification of a reinforced concrete element using the fiber section method. At first, the theory related to the fiber section approach and hysteresis models used for cyclic analysis is given.
Vatanshenas Ali
doaj +1 more source