Modelling Dynamically Re-sizeable Electrodes (DRE) for Targeted Transcutaneous Measurements in Impedance Plethysmography [PDF]
Impedance plethysmography of extremities typically uses band electrodes around limbs to monitor changes in blood volume. This often causes monitored blood variations to only generate minuscule impedance values relative to the measured baseline ...
Constantinou, L. +2 more
core +1 more source
Introduction: Gestational diabetes, which is defined as any degree of glucose intolerance first seen during pregnancy, is increasing in prevalence in India.
Smitha Bhat, K Sudeep, Rajesh K Jain
doaj +1 more source
A Novel, Contactless, Portable “Spot-Check” Device Accurately Measures Respiratory Rate [PDF]
Respiratory rate (RR) is an important vital sign used in the assessment of acutely ill patients. It is also used as to predict serious deterioration in a patient's clinical condition.
Burke, Derek +9 more
core +2 more sources
Nonhuman primates are often used to investigate physiologic processes that occur in man during aerospace/cardiovascular orthostatic research. Few studies have compared nonhuman primates and man under identical test conditions to assess the degree of ...
Montgomery Leslie David, Oloff Clarence
doaj +1 more source
Electrochemical Properties of PEDOT:PSS/Graphene Conductive Layers in Artificial Sweat
Electrodes based on PEDOT:PSS are gaining increasing importance as conductive electrodes and functional layers in various sensors and biosensors due to their easy processing and biocompatibility.
Boriana Tzaneva +4 more
doaj +1 more source
Background: Wearable and unobtrusive sensing devices are rapidly evolving for long-term cardiovascular monitoring. However, most of the cardiovascular device requires multi-channel physiological signals acquisition, especially in continuous blood ...
Ting-Wei Wang +6 more
doaj +1 more source
Impedance plethysmography as an alternative method for the diagnosis of peripheral arterial disease
Background and objective: In the diagnosis of peripheral artery disease (PAD), the ankle-brachial index (ABI) is considered as the standard, and other noninvasive methods have received too little attention.
Edita Mašanauskienė +4 more
doaj +1 more source
Systematic review and meta-analysis of the diagnostic accuracy of ultrasonography for deep vein thrombosis [PDF]
Background Ultrasound (US) has largely replaced contrast venography as the definitive diagnostic test for deep vein thrombosis (DVT). We aimed to derive a definitive estimate of the diagnostic accuracy of US for clinically suspected DVT and identify ...
A Cogo +133 more
core +5 more sources
Human skin model serving in electrical stimulation of Anterior Tibial Artery
Cardiac activities are one of the vital signs of life. To monitor these activities there are several methods including electrocardiography (ECG), photo plysthesmography, electrical impedance plythesmography. The purpose of the paper is to design external
Hina Shafi +3 more
doaj +1 more source
BackgroundAccurate assessment of body composition (BC) is important to investigate the development of childhood obesity. A bioelectrical impedance analysis (BIA) device is portable and inexpensive compared with air displacement plethysmography (ADP) for ...
Fangfang Chen +10 more
doaj +1 more source