Impedance plethysmography as an alternative method for the diagnosis of peripheral arterial disease [PDF]
Background and objective: In the diagnosis of peripheral artery disease (PAD), the ankle-brachial index (ABI) is considered as the standard, and other noninvasive methods have received too little attention.
Edita Mašanauskienė +4 more
doaj +2 more sources
A Cuffless Blood Pressure Measurement Based on the Impedance Plethysmography Technique [PDF]
In the last decade, cuffless blood pressure measurement technology has been widely studied because it could be applied to a wearable apparatus. Electrocardiography (ECG), photo-plethysmography (PPG), and phonocardiography are always used to detect the ...
Shing-Hong Liu +2 more
doaj +2 more sources
Limitations of Electric Impedance Plethysmography [PDF]
Electric impedance plethysmography has been offered as a substitute for mechanical plethysmography and would be particularly suitable for regions in which the mechanical method cannot be applied. A comparative investigation of mechanical and impedance plethysmograms, taken simultaneously from a finger or a forearm, revealed that, while the normal ...
Berg, J. van den, Jappe Alberts, A.
openaire +3 more sources
Introduction: Gestational diabetes, which is defined as any degree of glucose intolerance first seen during pregnancy, is increasing in prevalence in India.
Smitha Bhat, K Sudeep, Rajesh K Jain
doaj +1 more source
Nonhuman primates are often used to investigate physiologic processes that occur in man during aerospace/cardiovascular orthostatic research. Few studies have compared nonhuman primates and man under identical test conditions to assess the degree of ...
Montgomery Leslie David, Oloff Clarence
doaj +1 more source
Electrochemical Properties of PEDOT:PSS/Graphene Conductive Layers in Artificial Sweat
Electrodes based on PEDOT:PSS are gaining increasing importance as conductive electrodes and functional layers in various sensors and biosensors due to their easy processing and biocompatibility.
Boriana Tzaneva +4 more
doaj +1 more source
Background: Wearable and unobtrusive sensing devices are rapidly evolving for long-term cardiovascular monitoring. However, most of the cardiovascular device requires multi-channel physiological signals acquisition, especially in continuous blood ...
Ting-Wei Wang +6 more
doaj +1 more source
A comparison of impedance plethysmography and strain gauge plethysmography in the diagnosis of deep venous thrombosis in symptomatic outpatients [PDF]
Strain gauge plethysmography and impedance plethysmography are non-invasive diagnostic techniques for deep venous thrombosis. In 145 consecutive out-patients presented with suspected acute deep venous thrombosis we compared these two techniques ...
Huisman, M. V. +3 more
core +1 more source
Force Sensing Resistors Used as Plantar Impedance Plethysmography Electrodes [PDF]
Diabetic foot ulcers (DFUs) are an ominous consequence of diabetic foot. To develop a multidimensional lesion warning device, several variables must be considered, among which vascular parameters. To minimize the number of sensors, we investigate the use
Rafael Eliecer Gonzalez Landaeta +2 more
core +1 more source
Human skin model serving in electrical stimulation of Anterior Tibial Artery
Cardiac activities are one of the vital signs of life. To monitor these activities there are several methods including electrocardiography (ECG), photo plysthesmography, electrical impedance plythesmography. The purpose of the paper is to design external
Hina Shafi +3 more
doaj +1 more source