Results 191 to 200 of about 4,597 (239)
Some of the next articles are maybe not open access.
Plastic and Reconstructive Surgery, 1991
Vigilant postoperative monitoring of the buried muscle flap is critical after free transfer because early diagnosis of vascular insufficiency is essential to allow prompt correction. We have identified a monitoring method utilizing needle electrodes and impedance plethysmography that gives a beat-to-beat representation of muscular perfusion.
M J, Concannon +3 more
openaire +2 more sources
Vigilant postoperative monitoring of the buried muscle flap is critical after free transfer because early diagnosis of vascular insufficiency is essential to allow prompt correction. We have identified a monitoring method utilizing needle electrodes and impedance plethysmography that gives a beat-to-beat representation of muscular perfusion.
M J, Concannon +3 more
openaire +2 more sources
Errors in four-electrode impedance plethysmography
Medical & Biological Engineering & Computing, 1983The errors in electrical impedance plethysmography are not well known. In the paper errors due to inadequate instrumentation, improper electrode application, and physiological changes have been analysed. Minimum electrical requirements for a general purpose four-electrode instrument are: (a) input impedance of voltage-sensing circuit+4 kΩ; (b) output ...
D K, Swanson, J G, Webster
openaire +2 more sources
Impedance plethysmography on the arms: Respiration monitoring
2010 IEEE International Conference on Bioinformatics and Biomedicine Workshops (BIBMW), 2010A new method for extracting respiratory rate from electrical impedance measured on the arms is presented. The method requires application of only four electrodes to the subject's arms and is suitable to be used in a portable respiratory rate monitor and decision making systems. Set-Membership filtering is used to reduce the effect of motion artifact on
Sardar Ansari +3 more
openaire +1 more source
Electrical Impedance Plethysmography
Archives of Internal Medicine, 1962Plethysmography has proven to be a valuable method for studying the dynamics of peripheral vascular beds in normal and pathologic states and for evaluating the effects of drugs upon these beds. Refinements of the method, such as graded outflow hindrance and stopflow studies, have permitted separation of the pulsatile arterial inflow and venous runoff ...
openaire +1 more source
Positional Factors in Venous Impedance Plethysmography
Archives of Surgery, 1973To determine whether leg position or distance between the inner electrodes affect the magnitude of impedance change during deep inspiration, 30 adult patients (60 limbs) were studied with the Minnesota Impedance Cardiograph. Phlebography was performed in 19 limbs and correlated with the impedance findings.
F E, Deuvaert +2 more
openaire +2 more sources
Clinical Orthopaedics and Related Research, 1989
Impedance plethysmography (IPG) is a useful noninvasive detection of proximal segment thrombosis. Seven hundred patients treated with total hip arthroplasty were examined preoperatively and several times postoperatively using this technique. Twenty-one abnormal IPG results were obtained, and venography confirmed that 12 of these patients had proximal ...
P E, Ward +5 more
openaire +2 more sources
Impedance plethysmography (IPG) is a useful noninvasive detection of proximal segment thrombosis. Seven hundred patients treated with total hip arthroplasty were examined preoperatively and several times postoperatively using this technique. Twenty-one abnormal IPG results were obtained, and venography confirmed that 12 of these patients had proximal ...
P E, Ward +5 more
openaire +2 more sources
Intracardiac Impedance Plethysmography
American Journal of Physiology-Legacy Content, 1953R F, RUSHMER +3 more
openaire +2 more sources