Results 61 to 70 of about 9,828 (215)

RRAM Variability Harvesting for CIM‐Integrated TRNG

open access: yesAdvanced Electronic Materials, EarlyView.
This work demonstrates a compute‐in‐memory‐compatible true random number generator that harvests intrinsic cycle‐to‐cycle variability from a 1T1R RRAM array. Parallel entropy extraction enables high‐throughput bit generation without dedicated circuits. This approach achieves NIST‐compliant randomness and low per‐bit energy, offering a scalable hardware
Ankit Bende   +4 more
wiley   +1 more source

Enhanced Resistive Switching Uniformity in Tantalum Oxide Memristor Devices via Copper Implantation

open access: yesAdvanced Electronic Materials, EarlyView.
Metal oxide memristor devices typically suffer from uncontrolled forming processes and limited resistive switching uniformity due to the stochastic formation of an oxygen vacancy filament. Improved resistive switching uniformity in Ta2O5 memristor is developed by Cu implantation in the switching oxide.
Shaochuan Chen, Ilia Valov
wiley   +1 more source

PMU’s Behavior with Flicker-Generating Voltage Fluctuations: An Experimental Analysis

open access: yesEnergies, 2019
Phasor measurement units (PMUs), which are the key components of a synchrophasor-based wide area monitoring system (WAMS), were historically conceived for transmission networks.
Paolo Castello   +3 more
doaj   +1 more source

A Software-based Low-Jitter Servo Clock for Inexpensive Phasor Measurement Units

open access: yes, 2018
This paper presents the design and the implementation of a servo-clock (SC) for low-cost Phasor Measurement Units (PMUs). The SC relies on a classic Proportional Integral (PI) controller, which has been properly tuned to minimize the synchronization ...
Brunelli, Davide   +4 more
core   +1 more source

Ion‐Gating Reservoir Computing for Preprocessing‐Free Speech Recognition from Throat Vibrations

open access: yesAdvanced Electronic Materials, EarlyView.
This work presents a throat‐mounted mechanoelectric sensor integrated with an ion‐gel/graphene reservoir device for on‐device speech recognition. The system converts raw biomechanical vibrations into rich nonlinear current dynamics, enabling efficient classification through a simple linear readout. The approach highlights a compact and tunable physical‐
Daiki Nishioka   +5 more
wiley   +1 more source

A Framework for Phasor Measurement Placement in Hybrid State Estimation via Gauss-Newton

open access: yes, 2013
In this paper, we study the placement of Phasor Measurement Units (PMU) for enhancing hybrid state estimation via the traditional Gauss-Newton method, which uses measurements from both PMU devices and Supervisory Control and Data Acquisition (SCADA ...
Chang, Tsung-Hui   +2 more
core   +1 more source

Influence of Top Electrode Metal on Resistive Switching in Multilayer MOCVD MoS2 Memristors

open access: yesAdvanced Electronic Materials, EarlyView.
MoS2 memristors typically use evaporated noble metal electrodes. This study compares Pd, Ni, and Al electrodes and sputtered versus evaporated deposition. Pd is passive, while Ni damages MoS2, yielding poor switching. Sputtered Al enables reproducible ECM‐type switching with 95% yield, whereas evaporated Al forms an interfacial oxide that suppresses ...
Dennis Braun   +15 more
wiley   +1 more source

Decoding Tattoo and Permanent Makeup Pigments: Linking Physicochemical Properties to Absorption, Distribution, Metabolism, and Elimination Profiles Using Quantitative Structure–Activity Relationship (QSAR)‐Based New Approach Methodologies (NAMs)

open access: yesAdvanced Intelligent Discovery, EarlyView.
This study applies QSAR‐based new approach methodologies to 90 synthetic tattoo and permanent makeup pigments, revealing systemic links between their physicochemical properties and absorption, distribution, metabolism, and elimination profiles. The correlation‐driven analysis using SwissADME, ChemBCPP, and principal component analysis uncovers insights
Girija Bansod   +10 more
wiley   +1 more source

Optimization of Phasor Measurement Unit (PMU) Placement in Supervisory Control and Data Acquisition (SCADA)-Based Power System for Better State-Estimation Performance

open access: yesEnergies, 2018
Present-day power systems are mostly equipped with conventional meters and intended for the installation of highly accurate phasor measurement units (PMUs) to ensure better protection, monitoring and control of the network. PMU is a deliberate choice due
Mohammad Shoaib Shahriar   +2 more
doaj   +1 more source

Printed Wearable Sweat Rate Sensor for Continuous In Situ Perspiration Measurement

open access: yesAdvanced Intelligent Systems, Volume 7, Issue 3, March 2025.
A wireless wearable sweat rate sensor system is presented, featuring digital 3D direct‐write printing on a flexible substrate with microfluidic layers for continuous, real‐time monitoring. Printed encapsulated metal electrodes are used for capacitance measurements, achieving high sensitivity (0.01 μL min−1) while maintaining a compact and lightweight ...
Mohammad Shafiqul Islam   +6 more
wiley   +1 more source

Home - About - Disclaimer - Privacy