Results 51 to 60 of about 1,701 (169)
Historical Evolution of Electrodes and Their Impact on Electrochemical Sensing and Biosensing
This review outlines the historical development of electrodes and their importance in electrochemical sensing and biosensing. Electrode design and material choice directly influence sensitivity, selectivity, and applicability.
Pramod K. Kalambate, Devaraj Manoj
doaj +1 more source
The potassium phosphate buffer as a supporting electrolyte of anticancer drug (5-fluorouracil (5-FU)) was the best among solutions of sodium phosphate buffer and Britton Robinson buffer in differential pulse polarography (DPP) at pH = 7.0 and T = 37 ...
Razzaq Abd Al-Zahra Ibrahim +2 more
doaj +1 more source
Voltammetric Behaviour of Metronidazole at Mercury Electrodes
Metronidazole is the most important drug of the group of 5-nitroimidazoles and possesses toxicity to anaerobic micro-organisms DNA being the main target for their biological action.
La-Scalea Mauro A. +2 more
doaj
A differential pulse polarographic method for a quantitative analysis of chloramphenicol residue in milk had been developed. Result showed that the method using dropping mercury electrode as working electrode, Ag/AgCl electrode as reference electrode ...
Daryono Hadi Tjahjono +2 more
doaj +1 more source
Electrochemical Investigation of Mo(VI)-MTB-ClO-3 System in Phosphate Buffer [PDF]
The reduction mechanism of molybdenum-methyl thymol blue (MTB)-chlorate system has been investigated in water on a mercury electrode. As this system is very sensitive for ultratrace determination of molybdenum, the actual mechanism involved was studied ...
Afsaneh Safavi, Esmaeil Shams
doaj
The differential pulse polarography technique was used to establish an electroanalytical procedure for the determination of the organophosphorous insecticide methyl parathion (O,O-dimethyl O-(4-nitrophenyl) phosphorothioate) in soil samples.
Castanho Giuliane M. +2 more
doaj
Electrochemical Methods for the Analysis of Trace Tin Concentrations-Review. [PDF]
Grabarczyk M, Wlazlowska E, Fialek M.
europepmc +1 more source
Voltammetric Behaviour and Analysis of Fluchloralin
The electrochemical reduction behavior of fluchloralin has been studied by D.C.polarography, differential pulse polarography, millicoulometry and controlled potential electrolysis in the universal buffers ranging from 2.0 to 12.0. Kinetic parameters were
K. Balaji +4 more
doaj +1 more source
Pengaruh Diameter Katoda pada Sensitivitas Pengukuran Gradien Kecepatan dengan Metode Polarografi
Wall velocity gradient measurement using polarography gives very accurate output due to the absence of problem in fluid flow. Therefore this experiment is highly recommended. Based on the polarogram resulted in the polarography method, the potential that
Sukamta Sukamta
doaj
An Electrochemical Study of the S-Derivatives of 2-Amino Cyclopentene-1-Dithiocharboxylic Acid in Aqueous Ethanolic Media [PDF]
A systematic study on the electrochemical behavior of the S-derivatives of 2-amino cyclopentene-1-dithiocarboxylic acid (ACDA) has been carried out in aqueous ethanolic solutions by means of polarography, coulometry and voltammetry.
Afsaneh Safavi, Mohammad Bagher Golivand
doaj

