Results 51 to 60 of about 8,691,361 (197)

Laser‐Textured Field‐Engineered Interface for Robust Dry‐Processed Cathodes in Lithium‐Ion Batteries

open access: yesENERGY &ENVIRONMENTAL MATERIALS, EarlyView.
Laser‐patterned dry electrodes applied to current collectors could serve as a promising alternative to the limitations of conventional dry electrodes. Laser technology provides a fast and simple method to enhance the surface roughness of current collectors, improving the adhesion at the electrode–current collector interface.
Chaerin Jung   +8 more
wiley   +1 more source

A Comprehensive Review of Fault‐Current Limiter Technologies for Smart and Resilient Power Systems

open access: yesEnergy Science &Engineering, EarlyView.
This review compares superconducting, solid‐state, and hybrid fault‐current limiters (FCLs) for modern alternating current, direct current, and hybrid grids. It shows that optimal FCL selection depends on fault characteristics, network configuration, voltage level, protection coordination, and resilience requirements rather than on a universally ...
Abdelrahman Farghly   +5 more
wiley   +1 more source

ESTIMATION OF THE EFFECT OF VARIOUS METHODS AND DEVICES OF IMPULSE OVERVOLTAGE PROTECTION IN THE OIL FIELD ELECTRIC NETWORK 6–10 kV

open access: yesИзвестия Томского политехнического университета: Инжиниринг георесурсов, 2019
Relevance. One of the main causes of high accident rate and outages in distributed power supply systems of 6–10 kV oil fields are overvoltages due to lightning effects.
Sergey V. Sidorov   +2 more
doaj   +1 more source

A Preventive Static Security Control Strategy for Distribution Networks Based on Phase Shifting Transformer Loop‐Closing Devices

open access: yesIEEJ Transactions on Electrical and Electronic Engineering, EarlyView.
As the share of renewable energy in the energy mix continues to increase, the penetration of distributed renewable generation in distribution networks is also rising steadily. Loop‐closing operation provides an effective means to enhance renewable energy accommodation across different grid partitions.
Ningyu Zhang   +6 more
wiley   +1 more source

Evaluation Methodology, Numerical Verification and Retrofilling Procedure for Power Transformers to Ensure K‐Class Flame Retardancy and Environmentally Friendly

open access: yesHigh Voltage, EarlyView.
ABSTRACT With increasing demands for fire safety and environmental friendliness, retrofilling transformers with alternative insulating liquids has become a growing trend. However, retrofilling power transformers remains uncertain, as more residual mineral oil compromises K‐class flame retardancy, and its impact on environmental performance has yet to ...
Zhenfu Tang   +5 more
wiley   +1 more source

Voltage Rise Mitigation in PV Rich LV Distribution Networks Using DC/DC Converter Level Active Power Curtailment Method

open access: yesEnergies, 2022
In low voltage (LV) distribution systems, the problem of overvoltage is common during the lower load intervals. This problem arises because of the high value of R/X ration of these systems. Many techniques are available in literature to cope up with this
Pankaj Verma   +6 more
doaj   +1 more source

Arc Resistance Enhancement of Converter Transformer Tank Through Structural Improvements: Simulation and Experimental Validation

open access: yesHigh Voltage, EarlyView.
ABSTRACT Currently, limited research exists on the structural response and protection methods of the converter transformer tank for ± 800 kV ultra‐high voltage direct current transmission project to high energy arc faults. This research investigates the dynamic response and the vulnerable areas of the ultra‐high voltage converter transformer under the ...
Ke Wang   +5 more
wiley   +1 more source

Fast frequency model of overvoltage in adjustable speed drives : SiC technology vs IGBT technology

open access: yes, 2018
International audienceThe use of fast semiconductor components such as IGBT and SiC in Adjustable Speed Drives (ASD) increases power density and provides better controllability.
Belinger, Antoine   +4 more
core   +2 more sources

Generator step up transformer overvoltage protection in EPS power plants [PDF]

open access: yes, 2015
This paper presents the current state of the overvoltage protection of generator transformers in power plants of the Power Company of Serbia (EPS) and gives a critical overview of their overvoltage protection.
Mrvić Jovan   +2 more
core   +1 more source

Time to Breakdown for Type I Motor Winding Insulation Under High‐Frequency High‐Slew‐Rate Square Wave Voltages

open access: yesHigh Voltage, EarlyView.
ABSTRACT The emergence of (ultra)wide bandgap ((U)WBG)‐based devices has significantly enhanced performance in high‐frequency switching applications, enabling breakthroughs in electric transportation, aerospace, and renewable energy systems. However, it also presents considerable challenges to insulation systems, such as electric motor winding ...
Easir Arafat   +3 more
wiley   +1 more source

Home - About - Disclaimer - Privacy