Results 61 to 70 of about 7,321,935 (205)

The Impact of Various Contact Structures on the Microscopic Surface Condition of Vacuum Interrupters During Capacitive Switching

open access: yesHigh Voltage, EarlyView.
ABSTRACT The double‐break vacuum circuit breakers (VCBs) that utilize series break technology effectively increase the switching capability for capacitive currents, elevate the withstand voltage level, and reduce the likelihood of restrike, all without compromising the breaking capacity for short‐circuit currents.
Yun Geng   +6 more
wiley   +1 more source

Two-Stage Optimal Configuration Strategy of Distributed Synchronous Condensers at the Sending End of Large-Scale Wind Power Generation Bases

open access: yesEnergies
The transmission end of large-scale wind power generation bases faces challenges such as high AC-DC coupling strength, low system inertia, and weak voltage support capabilities.
Lang Zhao   +5 more
doaj   +1 more source

Zero‐Current Switching Based Model Predictive Control of a Double‐Extended Overlapped Alternate Arm Converter Used in the VSC–HVDC System

open access: yesHigh Voltage, EarlyView.
ABSTRACT The alternate arm converter (AAC) is one of the most efficient multilevel topologies based on voltage source converters (VSCs), which has recently gained attention in various applications, particularly in high voltage direct current (HVDC) systems.
Ehsan Akbari, Milad Samady Shadlu
wiley   +1 more source

Comprehensive Design and Experimental Validation of 30 kV Ultra‐Fast Flexible Controllable Arresters for HVDC Systems

open access: yesHigh Voltage, EarlyView.
ABSTRACT To effectively suppress transient overvoltages in HVDC systems, the design and experimental validation of a multi‐module series controllable arrester are presented. The voltage‐limiting performance, series voltage equalisation capability, and robustness under fault conditions in high‐voltage scenarios require further research.
Tai Yang   +4 more
wiley   +1 more source

High-frequency oscillations in a power transformer

open access: yes, 2001
Power transformers are widely used as step-up or step-down devices and they can offer galvanic isolation between the input of the power supply and the output.
Ranstad, P   +5 more
core   +1 more source

Study on the Power‐Frequency Arc Extinction Characteristics of Semi‐Closed Short‐Gap Device

open access: yesHigh Voltage, EarlyView.
ABSTRACT Multi‐chamber arc‐extinguishing devices have a simple structure and excellent arc‐extinguishing performance; thus, they have attracted considerable attention as lightning protection devices. However, the structural parameters of different models of the aforementioned devices vary, leading to inconsistent protection levels; therefore, the arc ...
Yeqiang Deng   +4 more
wiley   +1 more source

The Lightning Protection Assessment of Distribution Lines with Considering Frequency Grounding System [PDF]

open access: yesIranian Journal of Electrical and Electronic Engineering
Ensuring the protection of all components within power systems from lightning-induced overvoltage is crucial. The issue of power interruptions caused by both direct and indirect lightning strikes (LS) presents significant challenges in the electrical ...
Aida Gholami   +2 more
doaj  

Research Progress in Treeing Phenomena of Polypropylene Insulation Materials

open access: yesHigh Voltage, EarlyView.
ABSTRACT Polypropylene (PP) is increasingly utilised in high‐voltage systems due to its superior electrical and thermal properties. However, electrical treeing poses a significant threat to its long‐term reliability, potentially leading to insulation failure.
Boxue Du, Heyu Wang, Zhonglei Li
wiley   +1 more source

Machine Learning‐Assisted Development in Insulating Materials for High Voltage Applications

open access: yesHigh Voltage, EarlyView.
ABSTRACT The advancement of power systems imposes increasingly stringent performance requirements on insulating materials, making the development of high‐performance insulating materials a critical challenge in the field of electrical engineering. Traditional material development relies heavily on empirical trial‐and‐error approaches, which are time ...
Yichen Ran   +17 more
wiley   +1 more source

Design of Zero Overvoltage Switching tailored power electronics

open access: yes
25102517Zero Overvoltage Switching (ZOS) can be used for clean switching transitions without overvoltage oscillations and unlimited switching speed, leading to the elimination of switching losses.
März, Martin   +2 more
core   +1 more source

Home - About - Disclaimer - Privacy