Results 61 to 70 of about 8,691,361 (197)
Rare Lightning and Convection Characteristics During Two Successive Tornadoes in Southern China
ABSTRACT Systematic investigations into lightning characteristics of tornado storms in China remain scarce. This study comprehensively analyses rare lightning behaviour and overshooting top characteristics for two successive tornadoes during a long‐lived supercell in southern China on 27 April 2024.
Fengquan Li +9 more
wiley +1 more source
Comparing frequency‐dependent and distributed parameter with lumped losses power cable line models for cable insulation coordination against overvoltages [PDF]
Simulations of transients are an obliged step for the insulation coordination of cable lines. Although a frequency‐dependent power cable line model better takes into account real conditions since resistive and inductive parameters vary with frequency, a distributed parameter with lumped losses power cable models can be useful to simplify and give ...
Massimo Marzinotto, Giuseppe Pelliccione
openaire +1 more source
Load Rejection Overvoltage Suppression and Parameter Design Method of UHV AC Transmission Line
UHV (ultra-high voltage) by instant AC transmission system is accompanied by huge reactive power transmission. When the load drops sharply, it is easy to produce serious power frequency overvoltage, which is also defined as load rejection overvoltage ...
Wang Ma +6 more
core +1 more source
The relevance of the study: At the present stage of CIS countries network development the problem of increase the operation reliability of transformers, which main part has been already out of date is of the first-priority. The problem is also up to date
Myroslav Sabat +3 more
doaj +2 more sources
ABSTRACT The double‐break vacuum circuit breakers (VCBs) that utilize series break technology effectively increase the switching capability for capacitive currents, elevate the withstand voltage level, and reduce the likelihood of restrike, all without compromising the breaking capacity for short‐circuit currents.
Yun Geng +6 more
wiley +1 more source
ABSTRACT The alternate arm converter (AAC) is one of the most efficient multilevel topologies based on voltage source converters (VSCs), which has recently gained attention in various applications, particularly in high voltage direct current (HVDC) systems.
Ehsan Akbari, Milad Samady Shadlu
wiley +1 more source
ABSTRACT To effectively suppress transient overvoltages in HVDC systems, the design and experimental validation of a multi‐module series controllable arrester are presented. The voltage‐limiting performance, series voltage equalisation capability, and robustness under fault conditions in high‐voltage scenarios require further research.
Tai Yang +4 more
wiley +1 more source
The Lightning Protection Assessment of Distribution Lines with Considering Frequency Grounding System [PDF]
Ensuring the protection of all components within power systems from lightning-induced overvoltage is crucial. The issue of power interruptions caused by both direct and indirect lightning strikes (LS) presents significant challenges in the electrical ...
Aida Gholami +2 more
doaj
Research on influencing factors of arc grounding over-voltage in mine power supply system
In order to comprehensively study influence factors such as grounding resistance, line resistance, fault location, grounding capacitance, interphase capacitance and arc ignition time on arc grounding over-voltage in mine power supply system, typical mine
LIU Jucai +6 more
doaj +1 more source
Design of Zero Overvoltage Switching tailored power electronics
25102517Zero Overvoltage Switching (ZOS) can be used for clean switching transitions without overvoltage oscillations and unlimited switching speed, leading to the elimination of switching losses.
März, Martin +2 more
core +1 more source

