Results 61 to 70 of about 1,562 (203)
Study on Impurity Particle Detection in Transformer Oil Based on Microflow Imaging Method
ABSTRACT The concentration of particles in transformer oil has a significant influence on its electrical performance, making oil cleanliness a critical parameter in the operation and maintenance of power transformers. However, the light obstruction (LO) method recommended by current standards has inherent limitations, including low sensitivity to ...
Chen Chen +6 more
wiley +1 more source
The transmission end of large-scale wind power generation bases faces challenges such as high AC-DC coupling strength, low system inertia, and weak voltage support capabilities.
Lang Zhao +5 more
doaj +1 more source
ABSTRACT The emergence of (ultra)wide bandgap ((U)WBG)‐based devices has significantly enhanced performance in high‐frequency switching applications, enabling breakthroughs in electric transportation, aerospace, and renewable energy systems. However, it also presents considerable challenges to insulation systems, such as electric motor winding ...
Easir Arafat +3 more
wiley +1 more source
Rare Lightning and Convection Characteristics During Two Successive Tornadoes in Southern China
ABSTRACT Systematic investigations into lightning characteristics of tornado storms in China remain scarce. This study comprehensively analyses rare lightning behaviour and overshooting top characteristics for two successive tornadoes during a long‐lived supercell in southern China on 27 April 2024.
Fengquan Li +9 more
wiley +1 more source
Load Rejection Overvoltage Suppression and Parameter Design Method of UHV AC Transmission Line
UHV (ultra-high voltage) by instant AC transmission system is accompanied by huge reactive power transmission. When the load drops sharply, it is easy to produce serious power frequency overvoltage, which is also defined as load rejection overvoltage ...
Wang Ma +6 more
core +1 more source
ABSTRACT This paper investigates the generation mechanism of quasi‐power‐frequency resonant overvoltage triggered by multiple lightning strikes in high‐voltage alternating current (HVAC) systems equipped with shunt reactors. Based on field measurements from a 500 kV AC system, equivalent and simplified circuit models have been established to analyse ...
Tao Liang +7 more
wiley +1 more source
The Lightning Protection Assessment of Distribution Lines with Considering Frequency Grounding System [PDF]
Ensuring the protection of all components within power systems from lightning-induced overvoltage is crucial. The issue of power interruptions caused by both direct and indirect lightning strikes (LS) presents significant challenges in the electrical ...
Aida Gholami +2 more
doaj
Design of Hybrid Control Algorithm for Fault Ride-Through of Photovoltaic System
This paper proposes a novel control algorithm to enhance the fault ride-through (FRT) capability of a photovoltaic (PV) system. In this method, the overcurrent of the grid-tied inverter is suppressed to a preset value using model current predictive ...
Feng Zheng +5 more
doaj +1 more source
ABSTRACT The double‐break vacuum circuit breakers (VCBs) that utilize series break technology effectively increase the switching capability for capacitive currents, elevate the withstand voltage level, and reduce the likelihood of restrike, all without compromising the breaking capacity for short‐circuit currents.
Yun Geng +6 more
wiley +1 more source
Half-wavelength AC transmission (HWACT) is an ultra-long distance AC transmission technology, whose electrical distance is close to half-wavelength at the system power frequency. It is very important for the construction and operation of HWACT to analyze
Xuankun Song +6 more
doaj +1 more source