Results 81 to 90 of about 641,410 (267)
A distributed secondary control strategy for low‐voltage resistive AC microgrids is proposed, where consensus‐based algorithms dynamically adjust both the slope and offset of V‐I droop characteristics. This dual adaptation enables accurate proportional power sharing and effective voltage regulation at the PCC, while ensuring fast transient response and
Afshin Hasani +2 more
wiley +1 more source
Lightning Overvoltage Response Modeling and Protection Design for Solid State Transformer
The rapid development of the AI and ICT industry has driven massive data center construction. Compared to conventional LFT (line-frequency transformer)-isolated conversion system, SST-based uninterruptible power supply solution offers high efficiency ...
Jiatong Zhang +4 more
doaj +1 more source
Peducing the frequency of switching overvoltage in generator networks
THE PURPOSE of the study is to study the problem of switching overvoltages in 10 kV generator networks. Using the Matlab Simulink package, create a model of common auxiliaries of a 10/0.4 kV power station, calculate the overvoltage at different sections ...
R. Belsky +3 more
semanticscholar +1 more source
Multi‐Layer MTDC Protection: Design and Simulation Assessment
This study proposes a novel multi‐layer protection architecture for multi‐terminal DC systems that separates fault current‐limiting and interruption functions. By combining a thyristor‐based fault current limiter with an active resonance circuit breaker, the scheme significantly reduces peak fault currents and di/dt stress, enabling a more compact ...
Jong‐Geon Lee +3 more
wiley +1 more source
Optimal Dispatch of Residential Photovoltaic Inverters Under Forecasting Uncertainties
Efforts to ensure reliable operation of existing low-voltage distribution systems with high photovoltaic (PV) generation have focused on the possibility of inverters providing ancillary services such as active power curtailment and reactive power ...
Dall'Anese, Emiliano +3 more
core +1 more source
Equivalent Test Method for Fault Ride‐Through of Integrated Energy‐consuming MMC Modules
This paper proposes an equivalent assessment index covering the entire fault ride‐through process, taking the integrated energy‐consuming MMC valve as the research object, and solves the problem of the lack of assessment index for the fault ride‐through equivalent test.
Ying Li +7 more
wiley +1 more source
As voltage measuring devices are widely used in the high voltage power system with a primary‐secondary‐fusion structure, electronic voltage transformers are directly connected to the primary conductor and would face much more serious electromagnetic ...
Houda Zhu +5 more
doaj +1 more source
In order to avoid overvoltage in the power grid, shunt reactor is usually installed at both ends of long lines. As the power grid construction is expanding, long lines are often cut off and new substations are connected into the grid in order to improve ...
Bin CAO, Lifang MIAO, Shuai YUAN
doaj +1 more source
Distributed generation (DG) aggregation points are typically equipped with reactive compensation devices to maintain voltage stability. However, improper parameter design may cause harmonic oscillations due to interactions between the device and inverter impedance.
Chengjia Bao +4 more
wiley +1 more source
Virtual synchronous generator (VSG) control, which can provide inertia output, damp power oscillations, and offer frequency and voltage support to power grids, has become a growing trend in the control field of wind power generation. As a new technology,
Shuyi Wang +5 more
doaj +1 more source

