Results 11 to 20 of about 5,405,430 (295)
Switching on Power Harmonic Filters
In modern industrial power supply systems, there is observed rapid growth of time varying nonlinear loads having low power factor. The most adequate engineering solution for reactive power compensation of the loads is using compensation units including ...
Yuriy Varetsky
doaj +4 more sources
An 'active' passive-filter topology for low power DC/AC inverters [PDF]
This thesis was submitted for the degree of Doctor of Philosophy and awarded by Brunel University.This thesis presents a new output passive filter for voltage source inverter applications which is based on a shunt connected single tuned filter topology ...
Arman, Mahmoud Fayez
core +8 more sources
OpenDSS-Based Harmonic Power Flow Analysis for Distribution Systems With Passive Power Filters
The open distribution system simulator (OpenDSS) is open-source software developed by the Electric Power Research Institute (EPRI) in the United States for analyzing distribution systems.
Nien-Che Yang, Yu-Wei Hsu
doaj +1 more source
Harmonics Mitigation Filter for High-Power Applications
This research work proposes a cost-effective Hybrid Active Harmonic Filter (HAHF) method to mitigate current harmonics in an industrial or commercial power network. The proposed HAHF is based on a Silicon-Controlled Rectifier with an Electronic Inductor (SCR-EI) topology with a reduced number of fully active switches and a better harmonic performance ...
Ali Sunbul +2 more
openaire +6 more sources
Power quality improvement of sugar factories dc motor drive using hybrid filter [PDF]
Power quality management is the main problem facing industry today. This problem is mainly due to the generation of electric network harmonics. The growing use of variable speed drives produces a large amount of harmonics in distribution systems because ...
Mohamed Nosier +2 more
doaj +1 more source
Harmonic Elimination of 25 kV AC Electric Railways Utilizing a New Hybrid Filter Structure [PDF]
Thyristor rectifiers are widely used in electric railways in order to control the speed. As a consequence of their usage in addition to substantial input lead current, an enormous amount of harmonics is injected into the grid.
S. Yousefi +4 more
doaj +1 more source
A new method for power quality improvement [PDF]
This thesis was submitted for the degree of Doctor of Philosophy and awarded by Brunel University.A new control method for active power filters in conjunction with a passive filter circuit are presented and analysed in this thesis.
Kasikci, Ismail
core +6 more sources
The nonlinear characteristics of power electronic-based loads in a power system contribute a major role in the harmonics’ injection and other power quality disturbances. This affects the quality of the power supplied to consumers by distribution systems.
M. S. Priyadarshini +8 more
doaj +1 more source
New Topology of a Hybrid, Three-Phase, Four-Wire Shunt Active Power Filter
With a view to reducing harmonic content in electrical power systems, and, consequently, improving power quality level, filters and other harmonic compensation devices are widely used.
Stefani Freitas +5 more
doaj +1 more source
Comparative analysis of optimal damped and undamped passive filters using MIDACO-solver
Harmonic pollution is one of the challenging problems facing power networks recently due to the widespread non-linear loads and inverter-based renewables.
Nor Hidayah Abdul Kahar +5 more
doaj +1 more source

